Key Digital KD-IP922ENC Operating Instructions Manual page 17

Enterprise av over ip encoder
Hide thumbs Also See for KD-IP922ENC:
Table of Contents

Advertisement

30
Set Output x Audio Volume Up
Set Output x Audio Volume Down
Set Output x Audio Bass Freq. to yy, yy=[00-24],U,D
Set Output x Audio Middle Freq. to yy, yy=[00-24],U,D
Set Output x Audio Treble Freq. to yy, yy=[00-24],U,D
Network Setup
Set Output x Audio Delay to yy yy=[00-99],U,D
Set Output x Audio Mute Enabled/Disabled
Set Host IP Address to xxx.xxx.xxx.xxx
Set Net Mask to xxx.xxx.xxx.xxx
Set Router IP Address to xxx.xxx.xxx.xxx
Set TCP/IP Port to zzzz
Apply New Network Config
Set LAN Port1 by y [1=1G-BaseT, 2=100BaseT,
3=Auto]
Set LAN Port2 by y [1=1G-BaseT, 2=100BaseT,
3=Auto]
Set Group ID xxxx for Multicast, [0000=Unicast]
Set Front Panel Button E/D (E=Enable,D=Disable) xxxx R4, R2, Mute (Disable), R4, R2, Restore
Set RS232 Baud Rate to z bps [0=115200, 1=57600,
2=38400, 3=19200, 4=9600]
Rest Unit to Factory Default
R1, X, Volume, UP
R1, X, Volume, DOWN
R1, X, Bass, Y, Y
R1, X, Middle, Y, Y
R1, X, Treble, Y, Y
R1, X, LipSync, Y, Y
R1, X, Mute/Restore
R3, Bass, X, X, X, Video Mode, X, X, X,
Video Mode, X, X, X, Video Mode, X, X, X
R3, Middle, X, X, X, Video Mode, X, X, X,
Video Mode, X, X, X, Video Mode, X, X, X
R3, Treble, X, X, X, Video Mode, X, X, X,
Video Mode, X, X, X, Video Mode, X, X, X
R3, Volume, X, X, X, X
R3, All Restore
R3, 1, Audio Mode, X
R3, 2, Audio Mode, X
R4, Video Mode, X, X, X, X
(Enable)
R4, R2, Bass, Z
R4, R3, R2, R1, All Restore
Multi-Function I/O Ports
The three multi-function I/O ports can be configured as IR sensor, IR input, IR emitter,
RS-232, voltage trigger, or voltage sensor. However, there are limitations per port:
I/O Port
IR Sensor
IR Input
1
Yes
Yes
2
No
Yes
3
No
Yes
I/O port configurations:
IR sensor
Compatible port: I/O Port 1
»
Used for IR input or IR learning
»
Supported signal level: 0V – 5V
»
Supported IR frequency: 20kHz – 60kHz
»
IR Sensor (included) pinout:
»
Pin # (Phoenix)
Wire Color
1
Red
2
Black
3
White
Hardwired IR input
Compatible ports: 1, 2, and 3
»
Supports serial (hardwired) IR input with modulated IR signal
»
Supported signal level: 0V – 12V
»
Supported IR frequency: 20kHz – 100kHz
»
NOTE: Supports maximum of one (1) IR input at any time (sensor and hardwired)
»
IR Emitter
Serial RS-232
Trigger
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Note: Unit must be set to Compass
Control
Master Controller mode
®
if you wish to learn IR remote
Wire Signal
Power 5V
Ground
IR Signal
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kd-ip922dec

Table of Contents