Led Descriptions; Green Rf Signal Strength Led; Supervised Fire / Burg Input; Supervised Arm / Disarm Input - NAPCO StarLink SLE Installation Instructions Manual

Residential/commercial series
Table of Contents

Advertisement

RED DIAGNOSTIC LED (Labeled "D7")
YELLOW OPERATIONAL STATUS LED (Labeled "D4")
GREEN RF SIGNAL STRENGTH LED (Labeled "D3")
RED TROUBLE LED (Labeled "D5")
LED LOCATIONS
relay common. When used as arm/disarm status
input, a low indicates "armed" and a high indicates
"disarmed". For these inputs to report to a central
station, the radio must be configured with the cen-
tral station telephone number and correct reporting
formats and codes. See table on page 20 for more
information.
TB10: TIP: See TB11, below.
TB11: RING: Terminals TIP and RING: When used for
backup reporting, the house tip and ring telephone
wires must be routed from the outside to these ter-
minals.
Under normal back up conditions, these
terminals are internally wired to the PANEL TIP and
PANEL RING terminals, allowing all transmissions
to the central station to be monitored. These wires
are monitored for voltage such that if voltage falls
below 1.5V, a Telco Line Fault trouble is detected,
and the StarLink radio applies telephone line volt-
age to the control panel Tip and Ring allowing it to
receive and transmit any alarms sent by the control
panel.

Supervised Fire / Burg Input

8
Radio GND
(TB8)
(Alarm Panel)
10K
10K
C
TBL
The EOLR must be installed and located within the control panel housing.
StarLink
SLE Commercial Series Alarm Communicators -- Installation Instructions
D4 D3 D5
To StarLink
7
9
-or-
Terminals
IN2 (TB7)
-or-
IN3 (TB9)
(Radio)
N/C
C
N/C
Alarm
TB12: PANEL RING: See wiring diagrams.
TB13: PANEL TIP: See wiring diagrams.
Note: TB14-TB17 no connections permitted by UL.
TB14: RTS (R): See TB17 below.
TB15: PANEL TX (B): See TB17 below.
TB16: PANEL RX (G): See TB17 below.
TB17: CTS (Y): No connections permitted.

LED DESCRIPTIONS

The PC board contains several LED's, as follows:

GREEN RF SIGNAL STRENGTH LED

Labeled "D3", this LED is located at the lower right cor-
ner of the PC board.
Every 30 seconds, the StarLink radio receiver section
turns on and listens to the cell tower. Depending on the
signal strength detected, it will blink the Signal Strength
LED from 1 to 8 times, providing a signal strength indica-
tor that is updated constantly and is always displayed.
Refer to Coverage Table below.
Green LED Operation
Signal strength (as received by the radio) is displayed by
this LED blinking 1 to 8 times at a constant rate (with a
short delay between blink cycles).
level is greater than or equal to -91dBm (minimum 4
blinks at the mounting location).
GREEN RF SIGNAL STRENGTH LED
RADIO RECEIVER COVERAGE TABLE
LED Blinks
8
7
-55
-65
Power
(dBm)
YELLOW OPERATIONAL STATUS LED
Labeled "D4", this LED is located at the bottom right of
the PC board. Operation is as follows:

Supervised Arm / Disarm Input

8
Radio GND
(TB8)
10K
10K
The EOLR must be installed and located within the control panel housing.
Acceptable power
6
5
4
3
-75
-85
-91
-95
To StarLink
7
9
-or-
Terminals
IN2 (TB7)
IN3 (TB9)
(Radio)
(Alarm Panel)
C
Open = Disarmed
Closed = Armed