INTRODUCTION
The StarLink
alarm capture radio communicators are fully
supervised, wireless digital two-way subscriber units sup-
ported by an extensive nationwide wireless network. All
models are compatible with virtually any 12VDC alarm con-
trol panel and are easy to install and test (always adhere to
the documentation provided by the control panel manufac-
turer). All can function as a backup to existing telephone
lines, or as a primary communicator when telephone lines
are absent and when connected directly to the control pan-
el Telco terminals. When used as a backup communicator,
all units will automatically switch the communication chan-
nel from the telephone line to the network when telephone
line trouble is detected.
The StarLink radio communicators use proprietary data-
capture technology that captures the alarm report from the
control panel and transmits the alarm signals to the SLE
Control Center; the alarm signals are then forwarded to
ANY Central Station via standard CS receiver formats 4/2
RADIO REPORTING PATH
The diagram below shows the transmission path of a
signal from the radio to the central station.
1. Signal from a Control Panel.
2. StarLink
radio
transmission (from the TIP an RING wires); sends
RF signal through the network operator.
3. Network Operator, part of the vendor system,
a section of the cellular spectrum.
4. SLE Control Center (NOC), receives and
routes data.
5. Central Station.
StarLink
Radio
Control
Panel
(1)
(5)
CENTRAL
STATION
StarLink
SLE Series Alarm Communicators -- Installation Instructions
StarLink™ SLE Series
Alarm Communicators
INSTALLATION INSTRUCTIONS
receives
the
signal
(
(
(
(
(
(
(
)
(
)
(
)
(
)
(2)
(3)
Network
Operator
(4)
SLE Control Center
and Contact ID. In addition, the SLE Control Center gener-
ates and reports a Supervisory signal in the event that the
network does not receive the expected supervisory test
signal from the wireless communicator during a pre-
scheduled period. The following models are available:
SLE-GSM-3/4G - 2G, 3G and 4G Network Compatible
GSM alarm capture Communicator, SIM card included.
Black plastic enclosure.
SLE-GSM-8D-3/4G - 2G, 3G and 4G Network Compatible
GSM alarm capture Communicator. Supports remote
downloading to the Gemini GEM-P400, GEM-P800,
GEMP-801, Express XP-400 and XP-600 series control
panels. SIM card included. Black plastic enclosure.
SLE-CDMA - Universal CDMA alarm capture Communica-
tor. Black plastic enclosure.
SLE-CDMA-8D - Universal CDMA alarm capture Commu-
nicator. Supports remote downloading to the Gemini
GEM-P400, GEM-P800, GEMP-801, Express XP-400
and XP-600 series control panels. Black plastic enclo-
sure.
ADDITIONAL COMPONENTS
In addition to the models listed above, the following sub-
assemblies are available:
SLE-DLEXT - Optional, for up/downloading, extends dis-
tance from radio to panel, from 10 feet, up to 100 feet.
See installation instructions WI1950.
SLE-DLCBL - Download Cable, 6 feet.
SLE-SMTCHG - Smart Charge Module, optional charger /
power supply.
SLE-ANTEXT - Extended antenna with 15 feet of cable.
)
)
)
)
)
)
SPECIFICATIONS
The following specifications apply to all StarLink radio mod-
els unless otherwise stated:
Electrical Ratings for +12V (all models powered by the
control panel)
Input Voltage: 15-10.6VDC
Input Current: 65mA with peak RF transmission current of
400mA for models SLe-GSM-3/4G and SLE-CDMA; (80mA
with peak RF transmission current of 400mA for model SLe
-GSM-8D-3/4G and SLE-CDMA-8D)
WI1936E 12/14
1

Advertisement

Table of Contents
loading

Summary of Contents for NAPCO StarLink SLE Series

  • Page 1 INSTALLATION INSTRUCTIONS For Technical Service, (800) 645-9440 or visit us at http://tech.napcosecurity.com/ (Note: Technical Service is for security professionals only) Publicly traded on NASDAQ Symbol: NSSC © NAPCO 2014 WI1936E 12/14 INTRODUCTION ™ The StarLink alarm capture radio communicators are fully and Contact ID.
  • Page 2: Terminal Descriptions

    "armed" and a low indicates "disarmed". Located at the bottom of the StarLink radio PC board, the Note: When using Napco Armed Lugs (E4 or 17 terminals are described as follows: E15), do not use IN 1 for armed status; instead, use IN 2 or IN 3.
  • Page 3: Led Descriptions

    standby waiting for an alarm to report. Processing Alarm Conditions:  When processing an alarm, this LED will blink variably during each part of the process (dialing, handshaking, RED DIAGNOSTIC LED (Labeled "D7") data transmission, etc). RED TROUBLE LED Labeled "D5", this LED is located at the bottom right of the PC board.
  • Page 4: Network Coverage

     DO NOT mount the StarLink radio in non-climate con- PRIMARY AND BACK-UP REPORTING trolled environments (i.e. attics may become extremely hot in summer, garages may become extremely cold in The StarLink radio can function as a primary wireless winter). communicator, in cases where there are no telephone ...
  • Page 5  TB3: PGM1 (–). Normally low output wired to the REPORT CODES (Contact ID by default) (+) of a zone dedicated to monitoring the radio status. Should be programmed on Napco control panels as CONTACT ID PULSE Day Zone, but be programmed to sound locally and...
  • Page 6: Control Panel Programming

    A "4/2" receiver format programming example:  Method 1: Dedicate a panel zone to activate a trou- ble sounder when an open is detected. With Napco control panels, program a dedicated zone for Day Zone, Mini-sounder on Alarm and No Bell on Alarm. Wire the zone as indicated in the wiring diagrams further in this manual.
  • Page 7  Method 2: (Dedicated zone not required). If availa- ble, program the control panel for telephone supervi- sion. Program the StarLink radio using the Manage- ment Center "Advanced Features" screen www.napconoc.com) to enable Line Cut on all trou- bles. Note: Some control panels may require a differ- ent duration than the default time of 3 minutes.
  • Page 8 Wiring Diagram for PRIMARY Reporting Configuration GEM-P400 / GEM-P800 / Express XP-400 / Express XP-600 Control Panels (Use when telephone line is NOT available) (CONTROL PANEL HOUSING) CONTROL PANEL PC BOARD (–) AUX POWER (–) (TIP) (RING) ZONE (+) DEDICATED TO RADIO SUPERVISION Jumper (J600)
  • Page 9 Wiring Diagram for PRIMARY Reporting Configuration GEM-P400 / GEM-P800 / Express XP-400 / Express XP-600 Control Panels (Use when telephone line is NOT available) (CONTROL PANEL HOUSING) CONTROL PANEL PC BOARD 16VAC Transformer (–) AUX POWER (TIP) (–) (RING) 16VAC ZONE (+) DEDICATED TO (PROGRAMMED FOR)
  • Page 10 Wiring Diagram for BACKUP Reporting Configuration GEM-P400 / GEM-P800 / Express XP-400 / Express XP-600 Control Panels 16VAC Transformer (CONTROL PANEL HOUSING) CONTROL PANEL PC BOARD TO TELCO RING RJ31X (TELCO) (PHONE) AUX POWER (TIP) (TIP) (RING) (RING) (–) 16VAC Optional: When Power HOME Supply SLE-SMTCHG is not...
  • Page 11 Wiring Diagram for PRIMARY Reporting Configuration GEM-P801 Control Panel (Use when telephone line is NOT available) (CONTROL PANEL HOUSING) CONTROL PANEL PC BOARD TELCO T300 AUX POWER (–) ZONE (+) DEDICATED RJ31X TO RADIO SUPERVISION NON-POLARIZED Jumper (J600) (located only on NON-POLARIZED models SLE-CDMA- 8D and SLE-GSM-...
  • Page 12 Wiring Diagram for PRIMARY Reporting Configuration GEM-P801 Control Panel (Use when telephone line is NOT available) (CONTROL PANEL HOUSING) CONTROL PANEL PC BOARD 16VAC Transformer TELCO T300 AUX POWER (–) 16VAC Optional: When Power Supply SLE-SMTCHG is not used, connect Panel Aux Power to StarLink terminals 1 and 2 (observing polarity) RJ31X...
  • Page 13 Wiring Diagram for BACKUP Reporting Configuration GEM-P801 Control Panel 16VAC Transformer (CONTROL PANEL HOUSING) CONTROL PANEL PC BOARD TO TELCO TELCO RING T300 RJ31X AUX POWER (–) 16VAC Optional: When Power Supply SLE-SMTCHG is not used, connect Panel Aux Power to StarLink terminals 1 and 2 HOME (observing polarity)
  • Page 14 Wiring Diagram for PRIMARY Reporting Configuration GEM-X255 / GEM-P9600 / GEM-P3200 Control Panels (Use when telephone line is NOT available) (CONTROL PANEL HOUSING) Control Panel PC Board AUX POWER TEL LINE PHONE (–) RING TIP RING 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32...
  • Page 15 Wiring Diagram for BACKUP Reporting Configuration GEM-X255 / GEM-P9600 / GEM-P3200 Control Panels (CONTROL PANEL HOUSING) Control Panel PC Board 16VAC Transformer Summary of connections:  RJ31X RED to StarLink module 10 TO TELCO  RJ31X GREEN to StarLink module 11 ...
  • Page 16 Wiring Diagram for PRIMARY Reporting Configuration GEM-816 / GEM-P1632 / GEM-P1664, Freedom F-64 Control Panels (Use when telephone line is NOT available) (CONTROL PANEL HOUSING) Control Panel PC Board TELCO PHONE RING TIP RING 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 ZONE (+)
  • Page 17 Wiring Diagram for BACKUP Reporting Configuration GEM-816 / GEM-P1632 / GEM-P1664, Freedom F-64 Control Panels 16VAC (CONTROL PANEL HOUSING) Transformer Control Panel PC Board Summary of connections:  RJ31X RED to StarLink module 10 TO TELCO  RJ31X GREEN to StarLink module 11 Optional: When Power Supply SLE-SMTCHG is not ...
  • Page 18 Housing Template ™ StarLink SLE Series Alarm Communicators -- Installation Instructions...
  • Page 19 Notes ™ StarLink SLE Series Alarm Communicators -- Installation Instructions...
  • Page 20: Napco Limited Warranty

    In no event shall NAPCO be liable for an amount months following the date of manufacture. NAPCO in excess of NAPCO's original selling price of the...

Table of Contents