4. Input Selector Unit
(1) Remove the 2 screws attaching the Input Selector Unit.
(2) Pull up the Input Selector Unit and disconnect the connector.
Note:
Be careful in the attachment direction.
5. Top Panel Unit
(1) Remove the 6 screws from the both-sides side.
(2) Remove the 2 screws from the rear side.
(3) Remove the 5 screws from the front side.
(4) Remove the 4 screws from the bottom side.
(5) Pull up the front side of the Top Unit.
(6) Disconnect the connectors.
5