4. Function Settings
Incubation Condition Reset during Incubation
▶ It is used for resetting incubation environment easily during
automatic and manual incubation. In the screen during
incubation, press MANUAL button to see that temperature
set window flickers. To change temperature, reset its
number with UP / DOWN button and press ENTER button
to save set value with message/alarm sound, and move
cursor to the next step(temperature and humidity daily
temperature range time set and daily temperature range
temperature set).
In case of not wanting to change the numerical value of
incubation environment, press MANUAL button to move
to the next step. Also, in case of not pressing any button
for about 10 seconds, it is changed into incubation screen.
▶ You can go directly to the needed setting mode by pressing
MANUAL button several times according to your needs.
It can be used when you want to check the current incubation
condition during incubation.
▶ If you press ENTER button, LCD display indicates setting
Temperature & Humidity.
How to Turn ON/OFF Humidification Function
▶ In case of using without inserting water for humidification or in case of incubating at low humidity of less than
RH 40%, it is necessary to stop humidifying function.
▶ Press MANUAL button for 2 times and press DOWN button consecutively at humidity set until "OFF" is display
ed and press ENTER button to turn Off humidifying function. Reversely, set into more than RH 40% to turn On
humidifying function.
Chameleon
26.1
3Hr
80
0.0℃
2 times
[Humidification ON]
In case of using without putting water for humidification in or incubating at low humidity of less than RH 40%,
it is necessary to stop humidifying function. In case of not supplying water for humidification turning on
humidifying equipment, the humidifying unit part is damaged or the lifespan of part is shorten noticeably.
Be sure to turn OFF humidifying function equipment.
16
Rcom Reptile Incubator Pro 90 User Manual
(5) Incubation conditions reset /
How to Set Turn ON, OFF Humidification Function
HUMI. Set
26.1
3Hr
OFF
0.0℃
Chameleon
MANUAL
SHIFT
26.1
3Hr
80
0.0℃
* Press UP/DOWN button to select reptile
species and press ENTER.
Parameter saved
Setting Save Message
Chameleon
Parameter saved
5 times
[Humidification OFF]
DIGITAL INCUBATOR
UP
DOWN
ENTER
26.1
3Hr
OFF
0.0℃