Electronically controlled instantaneous water heater (44 pages)
Summary of Contents for Austria Email VACUMAIL series
Page 1
Operating and assembly instructions Pressure-proof electric water heater VACUMAIL of the model-series 50 bis 150 Liter Please pass on to the end user Id.Nr.: 234660-8 • GB...
Page 2
Dear Customer, Following your decision to purchase a hot water heater with an electric storage tank produced by our company We should like to thank you for selecting one of our products. We are supplying you with an attractively designed product that is built according to the state-of-the-art and which meets the currently applicable regulations.
Contents Page Function ....................4 Hot water requirements ...............4 Energysaving ..................4 Standby energy consumption .............5 4.1 Model series VACUMAIL .............5 Operation ....................5 6 . Temperature setting ................5 Operating prerequisites ...............6 Assembly and safety instructions ............6 Dimensional drawing ................7 10. Domestic hot water connection (Pressure-resistant) ......8 11.
1. Function The domestic hot water stored in the enamelled inner boiler is heated by the electrical heating element. The end-user can preselect the desired temperature on the setting toggle. The heating is switched on independently by the temperature control system during the heating-up times that have been set by the responsible electricity supply company and switched off after reaching the desired storage water temperature..
4. Standby energy consumption If a water heater is heated-up and no water is removed for a lengthy period of time after completion of the heating process, a somewhat slow but continuous cooling down of the stored water takes place over the surface of the appliance.
7. Operating pre-requisites The storage tanks are to be exclusively installed as per the conditions given on the rating plate. The maximum permitted pressure should correspond to the rated pressure stated on the rating plate. The connection conditions of the local electricity and water supply companies as well as the assembly and operating instructions are to be observed in addition to the legally recognised regulations and standards.
f) Thought should be given to the selection or to the order of sequence of the installation materials that are to be used with the equipment (take special care with mixed installations) in accordance with the rules of engineering with respect to any possible electrochemical processes (contact corrosion, for example in copper-steel).
10. Domestic hot water connection (pressure-resistant) All warranty for our hot water heaters will be invalidated in the event of the use of unsuitable or non- functioning storage tank connection fittings and any exceeding of the stated operating pressure. All hot water heaters which display the rated pressure 6 bar (atm or kp/cm2)on the rating plate are pressure-resistant storage tanks and can be connected up so that they are pressure-resistant with a line pressure of up to 5.5 bar (atm).
Execution: Operator, installing companies Time interval every 6 months Maintenance and Repairs: If there should be no water or a permanent leakage on the safety valve when the water heater is heating up, then the valve should be released by activating the lifting device several times or by trying to flush-out any foreign bodies (e.g.
14. Inspection, Maintenance, Care a) During the heating-up process, the expansion water must be seen to drip from the outlet of the sa- fety valve. When the unit is fully heated-up (approx. 80°C) the expansion water totals approximately 3.5% of the contents of the storage tank. The functioning of the safety valves should be inspected every month.
Warranty, Guarantee and Product Liability Warranty is made according to the legal provisions of the Republic of Austria and the EU. 1. The prerequisite for honoring of warranty terms on the part of the manufacturer (hereinafter referred to as Manu- facturer) is presentation of a paid invoice for the purchase of the appliance in question, whereby the identity of the appliance including model and fabrication number must be indicated on the invoice and presented by the claim ap- plicant.
Page 13
9. Transport damage will only be inspected and if appropriate recognized if it has been reported in writing to the manu- facturer no later than the weekday following delivery. 10. Claims exceeding the terms of the warranty, in particular those for damage and consequential damages, are precluded insofar as these are legally permissible.
Page 16
A-8720 Knittelfeld Telefon: (03512) 700-0 Fax: (03512) 700-239 Internet: www.austria-email.at E-Mail: office@austria-email.at Austria Email in your area? For addresses and telephone numbers of our subsidiaries, visit our homepage at www.austria-email.at Print errors and changes of all kinds are reserved. Reproduction prohibited.
Need help?
Do you have a question about the VACUMAIL series and is the answer not in the manual?
Questions and answers