Samsung AE120JXEDEH Installation Manual page 38

Air to water heat pump outdoor unit
Hide thumbs Also See for AE120JXEDEH:
Table of Contents

Advertisement

Number of
Display contents
press
14
Protective control
15
IPM temp.
long-1
Main Micom version
long-1 and 1 Inverter Micom version
long-1 and 2 EEPROM version
5. DIP Switching setting
KEY
K5
Heat Pump
K6
Anti-stack snow mode OFF
Silence operation
K7
K7
ON
ON
K8
OFF
OFF
6. Key function setting
ON
1 2 3 4
5 6
7 8
Segment 1
E
F
Year(Dec)
Year(Hex)
Year(Hex)
ON (default)
K8
ON
OFF
ON
OFF
ENGLISH-38
Display
Segment 2
Protective control
0 : No protective
0 : Cooling
2 : Defrosting
1 : Heating
3 : Over-load
4 : Discharge
5 : Total current
+/-
Month(Hex)
Day(two digit)
Month(Hex)
Day(two digit)
Month(Hex)
Day(two digit)
OFF
Heating Only
Anti-stack snow mode ON
Mode
Silence mode Step 1
Silence mode Step 2
Silence mode Step 3
Silence mode Step 1
Segment 3
Segment 4
Frequency status
control
0 : Normal
1 : Freezing
1 : Hold
2 : Down
3 : Up_limit
4 : Down_limit
10s digit
1s digit
Day(One digit)
Day(One digit)
Day(One digit)
Remark
In silence mode, no
guarantee of capacity
Units
-
°C
-
-
-