Trouble shooting

• Incorrect handling of thermostat, safety valve or other valves may lead to tank rupture. When servicing the unit
follow instructions carefully:
WARNING
• Always turn o main power supply when water supply is being shut o .
• Test the free operation of the safety valve regularly by opening the valve ensuring the water ows freely.
• Electrical connection and all servicing of the electrical components should only be carried out by an authorized
electrician.
• Fitting and all servicing of plumbing xtures should only be carried out by an authorized installer.
• When replacing the thermostat, safety valve or any other valve or part supplied with this unit, use only approved
parts of the same speci cation.

Error codes

If the unit has some problems and does not work normally, error code is shown on the OUTDOOR UNIT main PBA or LCD
of the wired remote controller.
Display
101
Hydro Unit / Outdoor Unit communication connection error
122
EVA Inlet temp sensor SHORT or OPEN
123
EVA Outlet temp sensor SHORT or OPEN
162
EEPROM Error
198
Error of Terminal Block's Thermal Fuse(Open)
201
Hydro Unit / Outdoor Unit communication error(Matching error)
202
Hydro Unit / Outdoor Unit communication error(3 min)
203
Communication error between INVERTER and MAIN MICOM (4 min)
221
Outdoor Unit air temperature sensor error
231
Condenser temperature sensor error
251
Discharge temperature sensor error
320
OLP sensor error
403
Detection of freezing (During cooling operation)
Protection of Outdoor Unit when it is overload (during Safety Start, Normal
404
operation state)
407
Comp down due to high pressure
416
Discharge of a compressor is overheated
419
OUTDOOR UNIT EEV operation error
425
Power source line missing error (only for 3-phase model)
440
Heating operation blocked (outdoor temperature over 35 °C)
441
Cooling operation blocked (outdoor temperature under 9 °C)
458
OUTDOOR UNIT fan1 error
461
[Inverter] Compressor startup error
462
[Inverter] Total current error/PFC over current error
Explanation
ENGLISH-44
Error Source
Hydro Unit
Hydro Unit
Hydro Unit
Hydro Unit
Hydro Unit
Hydro Unit/Ourdoor Unit
Hydro Unit/Ourdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit
Outdoor Unit