b.
Access the Advanced TACACS+ Settings page.
c.
Select Level 3 for the Max Privilege for any AAA Client option.
d.
Select the Use separate password option, and specify enabpass as the password.
Figure 23 Configuring advanced TACACS+ settings
Verifying the configuration
1.
Telnet to the switch, and enter the username test@bbb and password aabbcc to access the switch.
Verify that you have access to diagnostic commands.
<Switch> telnet 192.168.1.70
Trying 192.168.1.70 ...
Press CTRL+K to abort
Connected to 192.168.1.59 ...
******************************************************************************
* Copyright (c) 2004-2015 Hewlett-Packard Development Company, L.P.
* Without the owner's prior written consent,
* no decompiling or reverse-engineering shall be allowed.
******************************************************************************
login: test@bbb
Password: