Power Supply Voltage, Normal Operation; Radio Specifications - Wavecom GR64 GSM/GPRS Integrator's Manual

Wireless cpu
Table of Contents

Advertisement

10.2 Power supply voltage, normal operation

Parameter
VCC Supply voltage
Maximum allowable voltage drop
Maximum current consumed
WARNING

10.3 Radio specifications

Feature
Frequency range (MHz)
Maximum power
Antenna impedance
GR64 Integrators Manual
Page: 94/104
Stresses in excess of the absolute maximum limits can cause permanent
!
damage to the device. These are absolute stress ratings only. Functional
operation of the device is not implied at these or any other conditions in
excess of those given in the normal Min & Max values stated. Exposure
to absolute maximum ratings for extended periods can adversely affect
device reliability.
GSM850
824-894
33dBm (2W)
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged without prior written agreement.
Ce document est la propriété exclusive de WAVECOM. Il ne peut être communiqué ou divulgué à des tiers sans son autorisation préalable
Mode
Nominal
Min
Max
Absolute maximum
voltage range
Maximum supply
ripple
Transmission burst
Full power (2W)
transmit
E-GSM900
GSM1800
880-960
1710-1880
33dBm (2W)
30dBm (1W)
50 ohms
Limit
3.6 V
3.2 V
4.5 V
-0.3 to 6.5 V
<100mV @ <200kHz
<20mV @ >200kHz
200mV
2250 mA (peak)
2100 mA (average)
GSM1900
1850-1990
30dBm (1W)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents