Download Print this page

Gree GWH09TB-D3DNA1A Service Manual page 33

Refrigerant r410a
Hide thumbs Also See for GWH09TB-D3DNA1A:

Advertisement

Tpreset +5˚C(9ºF~10ºF)
Tpreset +2˚C(3ºF~4ºF)
Tamb.
6 min.
Compressor
Outdoor unit
Indoor unit
2 min.
4-way valve
Run
Heating mode Tpreset
=20ºC (68ºF)(if cooling-only
unit, it is Fan mode,
Tpreset=25ºC(77ºF))
Tpreset
3 min.
6 min.
Blow residual
heat
2 min.
Stop
Keep current
operation mode
21ºC(69ºF)
26ºC(79ºF)
Start heating
Previous running status
Start heating
Blow residual heat
Cooling mode,
Tpreset=25ºC(77ºF)

Advertisement