Advertisement

Split Air Conditioner
Thank you for choosing our product.
For proper operation, please read and keep this manual carefully .
If you have lost the Owner's Manual, please contact the local agent or visit
www.gree.com or sent email to global@gree.com.cn for electronic version.

Advertisement

Table of Contents
loading

Summary of Contents for Gree GWH09TA-K3DNA2B/I

  • Page 1 Thank you for choosing our product. For proper operation, please read and keep this manual carefully . If you have lost the Owner’s Manual, please contact the local agent or visit www.gree.com or sent email to global@gree.com.cn for electronic version.
  • Page 2 GWH09TA-K3DNA1B/I DRED GWH09TA-K3DNA2B/I DRED GWH12TB-K3DNA1B/I DRED GWH12TB-K3DNA2B/I DRED GWH18TC-K3DNA1B/I DRED GWH18TC-K3DNA2B/I DRED GWH24TD-K3DNA1C/I DRED GWH24TD-K3DNA2C/I DRED GWH28TD-K3DNA1B/I DRED GWH28TD-K3DNA2B/I DRED...
  • Page 3: Table Of Contents

    Content Operation Notices Precautions......................1 Parts name ......................6 Screen Operation Guide Buttons on remote controller .................7 Introduction for icons on display screen ..............7 Introduction for buttons on remote controller ............8 Introduction for special function ................13 Operation guide ....................15 Replacement of batteries in remote controller .............15 Emergency operation ..................16 Maintenance Clean and maintenance..................16...
  • Page 4: Precautions

    Precautions WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 5 Precautions WARNING Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. Do not extend fingers or objects into air inlet or air outlet.
  • Page 6 Precautions WARNING Attachment Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit break.
  • Page 7 Precautions WARNING Do not put through the power before finishing installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  • Page 8 Precautions WARNING For the air conditioner with plug, the plug should be reachable after finishing installation. For the air conditioner without plug, an circuit break must be installed in the line. If you need to relocate the air conditioner to another place, only the qualified person can perform the work.
  • Page 9: Parts Name

    Parts name Indoor Unit air inlet panel aux.button filter horizontal louver air outlet cooling power receiver indicator indicator window display heating temp. drying indicator indicator indicator (Display content or position may be different from above remote control graphics, please refer to actual products) NOTICE: Actual product may be different from above graphics, please refer to actual products.
  • Page 10: Buttons On Remote Controller

    Buttons on remote controller ON/OFF button FAN button MODE button +/- button TURBO button button button CLOCK button TIMER ON/ TIMER OFF button TEMP button button (before opening cover (after opening cover I FEEL button ON/OFF button LIGHT button FAN button X-FAN button QUIET button MODE button...
  • Page 11: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller Note: ●This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model don't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 12 Introduction for buttons on remote controller Presetting temperature can be decreased. Press this button, the temperature can be set up, continuously press this button and hold for two seconds, the relative co- ntents can quickly change, until unhold this button and send the order that the ℃ (℉) signal will be displayed all the time.
  • Page 13 Introduction for buttons on remote controller button, 2 seconds later, it quickly change, the way of change is: During the initial 2.5 seconds, ten numbers change in the one place of minute, then the one place is constant, ten numbers change in the tens place of minu te at 2.5 seconds speed and carry.
  • Page 14 Introduction for buttons on remote controller LIGHT button Press this button at unit On or Off status, Light On and Light Off can be set up. After powered on, Light On is defaulted. X-FAN button Pressing X-FAN button in COOL or DRY mode, the icon is displayed and the indoor fan will continue operation for 2 minutes in order to dry the indoor unit even though you have turned off the unit.
  • Page 15 Introduction for buttons on remote controller (4) When setting the initial temperature 30℃, under this temperature setting, after 7hours, the temperature will be decreased 1℃, after that the unit will keep on running under this temperature; In Heat mode: (1) Under the initial presetting temperature 16℃, it will run under this setting tem- perature all along.
  • Page 16: Introduction For Special Function

    Introduction for special function About X-FAN function This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould. 1. Having set X-FAN function on: After turning off the unit by pressing ON/OFF button indoor fan will continue running for about 2 min.
  • Page 17: About Switch Between Fahrenheit And Centigrade

    Introduction for special function About switch between Fahrenheit and Centigrade Under status of unit off, press MODE and - buttons simultaneously to switch ℃ and ℉. Combination of "TEMP" and "CLOCK" buttons: About Energy - saving Function Press “TEMP” and “CLOCK” simultaneously in COOL mode to start energy-saving fun- ction.
  • Page 18: Operation Guide

    Operation guide General operation 1. After powered on, press ON/OFF button, the unit will start to run. (Note: When it is powered on, the guide louver of main unit will close automatically.) 2. Press MODE button, select desired running mode. 3.
  • Page 19: Emergency Operation

    Emergency operation If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: As shown in the fig. Open panel, press aux. button to turn on or turn off the air conditioner.
  • Page 20: Clean Filter

    Clean and maintenance Clean filter Open panel Clean filter Pull out the panel to a certain ● Use dust catcher or water to angle as shown in the fig. clean the filter. ● When the filter is very dirty, use the water (below 45℃...
  • Page 21 Clean and maintenance NOTICE: Checking before use-season 1. Check whether air inlets and air outlets are blocked. 2. Check whether circuit break, plug and socket are in good condition. 3. Check whether filter is clean. 4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
  • Page 22: Malfunction Analysis

    Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Phenomenon Check items Solution ● Whether it's interfered severely ● Pull out the plug. Reinsert (such as static electricity,stable the plug after about 3min, and voltage)?
  • Page 23 Malfunction analysis Phenomenon Check items Solution ● Power failure? ● Wait until power recovery. ● Is plug loose? ● Reinsert the plug. ● Circuit break trips off or ● Ask professional to replace fuse is burnt out? circuit break or fuse. Air condit- ●...
  • Page 24 Malfunction analysis Phenomenon Check items Solution ● Whether there’s odour source, ● Eliminate the odour source. Odours are such as furniture and cigarette, emitted ● Clean the filter. etc. Air conditio- ● Whether there’s interference, ● Disconnect power, put back ner operates such as thunder, wireless power, and then turn on the...
  • Page 25: Error Code

    Malfunction analysis Error Code ● When air conditioner status is abnormal, temperature indicator on indoor unit will ation of error code. Above indicator diagram is only for reference. Please refer to Indoor actual product for the actual display indicator and position. Error code Error code Troubleshooting...
  • Page 26: Installation Dimension Diagram

    Installation dimension diagram Space to the wall At least 15cm...
  • Page 27: Tools For Installation

    Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note: ●...
  • Page 28: Requirements For Electric Connection

    Requirements for electric connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. 2. According to the local safety regulations, use qualified power supply circuit and circuit break. 3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction.
  • Page 29: Installation Of Indoor Unit

    Installation of indoor unit Step one: choosing installation location Recommend the installation location to the client and then confirm it with the client. Step two: install wall-mounting frame 1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the level meter and then point out the screw fixing holes on the wall.
  • Page 30 Installation of indoor unit Indoor outdoor Note: ● Pay attention to dust prevention and take relevant safety measures when opening the hole. ● The plastic expansion particles are Φ55/ 5-10° Φ70 not provided and should be bought locally. Step four: outlet pipe 1.
  • Page 31 Installation of indoor unit Hex nut diameter Tightening torque (N . m) open-end wrench Φ 6 15~20 Φ 9.52 30~40 union nut Φ 12 45~55 pipe Φ 16 60~65 torque wrench Φ 19 70~75 indoor pipe 4. Wrap the indoor pipe and joint of con- nection pipe with insulating pipe, and then wrap it with tape.
  • Page 32 Installation of indoor unit 2. Make the power connection cord go cable-cross through the cable-cross hole at the back hole of indoor unit and then pull it out from the front side. power connection cord 3. Remove the wire clip; connect the power connection cord to the wiring terminal according to the color;...
  • Page 33 Installation of indoor unit Step eight: bind up pipe 1. Bind up the connection pipe, power drain hose connection pipe band cord and drain hose with the band. indoor and outdoor power cord indoor unit pipe indoor power cord liquid pipe 3.
  • Page 34: Check After Installation

    Check after installation ● Check according to the following requirement after finishing installation. Items to be checked Possible malfunction Has the unit been installed firmly? The unit may drop, shake or emit noise. Have you done the refrigerant leakage It may cause insufficient cooling test? (heating) capacity.
  • Page 35 Configuration of connection pipe 1. Standard length of connection pipe ● 5m, 7.5m, 8m. 2.Min. length of connection pipe is 3m. 3.Max. length of connection pipe and max. high difference. Max length Max length Cooling Max height Cooling Max height of connec- of connec- capacity...
  • Page 36 Configuration of connection pipe Additional refrigerant charging amount for R22, R407C, R410A and R134a Diameter of connection pipe Outdoor unit throttle Liquid pipe(mm) Gas pipe(mm) Cooling only(g/m) Cooling and heating(g/m) Φ6 Φ9.52 or Φ12 Φ6 or Φ9.52 Φ16 or Φ19 Φ12 Φ19 or Φ22.2 Φ16...
  • Page 37 GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: gree@gree.com.cn www.gree.com 66160000061...

Table of Contents