Hydac MCS1510-5-0 Operation And Installation Manua

Hydac MCS1510-5-0 Operation And Installation Manua

Mcs 1000 series metallic contamination sensor
Table of Contents

Advertisement

MCS 1000 Series
Metallic
Contamination Sensor

Operation and Installation Guide

English (translation of original instructions)
Document no.: 3435427f
Valid from hardware index B and
firmware version V 1.30 up

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MCS1510-5-0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hydac MCS1510-5-0

  • Page 1: Operation And Installation Guide

    MCS 1000 Series Metallic Contamination Sensor Operation and Installation Guide English (translation of original instructions) Document no.: 3435427f Valid from hardware index B and firmware version V 1.30 up...
  • Page 2: Imprint

    Court of Registration: Saarbrücken, HRB 17216 Executive director: Mathias Dieter, Dipl.Kfm. Wolfgang Haering Documentation Representative Mr. Günter Harge c/o HYDAC International GmbH, Industriegebiet, 66280 Sulzbach / Saar Telephone: ++49 (0)6897 509 1511 Fax: ++49 (0)6897 509 1394 E-mail: guenter.harge@hydac.com ©...
  • Page 3: Table Of Contents

    Fastening the MCS 14xx ..................31 Fastening the MCS 15xx ..................32 Fastening MCS15xx via angle fastening set............33 Connecting MCS15xx via pipe adapter set............33 HYDAC FILTER SYSTEMS GMBH en(us) Page 3 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc...
  • Page 4 SWT.PLS - Set pulse length at the switching output ..........55 CANCEL - cancel without saving ................55 SAVE - Save changes ..................55 Error analysis / remedy..................56 HYDAC FILTER SYSTEMS GMBH en(us) Page 4 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc...
  • Page 5 EC declaration of conformity ................71 Glossary ........................72 Ferromagnetic (Fe) ....................72 Non-ferromagnetic (nFe) ..................72 Certification......................72 Basics of GL certification...................73 Germanischer Lloyd Industrial Services GmbH, renewable energies....73 HYDAC FILTER SYSTEMS GMBH en(us) Page 5 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 6: Preface

    If you discover errors while reading the documentation or have suggestions or other useful information, please don’t hesitate to contact us: HYDAC FILTER SYSTEMS GMBH Technische Dokumentation Postfach 12 51 66273 Sulzbach / Saar Germany We look forward to receiving your input.
  • Page 7: Technical Support

    After modification or repair work that affects the safety of the product has been carried out on components, the product may not be returned to operation until it has been checked and released by a HYDAC technician. Please notify us immediately of any modifications made to the product whether by you or a third party.
  • Page 8: Using The Documentation

    The documentation number with its index enables you to order another copy of the operating and maintenance instructions. The index is incremented every time the manual is revised or changed. HYDAC FILTER SYSTEMS GMBH en(us) Page 8 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc...
  • Page 9: Safety Information And Instructions

    MCS made by the user or purchaser  Improper monitoring of unit components that are subject to wear and tear  improperly performed repair work HYDAC FILTER SYSTEMS GMBH en(us) Page 9 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 10: Explanation Of Symbols And Warnings, Etc

    Improper use may result in hazard to life and limb. Improper use includes:  Improper connection of the MCS voltage and sensor cables  Operation with non-approved fluids. HYDAC FILTER SYSTEMS GMBH en(us) Page 10 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 11: Informal Safety Precautions

    Hydraulic systems are under pressure Danger of bodily injury ► The hydraulic system must be depressurized before performing any work on the hydraulic system. HYDAC FILTER SYSTEMS GMBH en(us) Page 11 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 12: Training And Instruction Of Personnel

    Activity Packing Transportation Commissioning Operation Troubleshooting/ locating the source of malfunction Remedying of mechanical faults Remedying of electrical faults Maintenance Repair work Decommissioning/storage HYDAC FILTER SYSTEMS GMBH en(us) Page 12 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 13: Storing The Mcs

    Model per model code Part no. Always list complete serial no. Date Year/week of production Index Hardware index Max. INLET press. Max. operating pressure in bar/psi HYDAC FILTER SYSTEMS GMBH en(us) Page 13 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 14: Checking The Mcs 13Xx Scope Of Delivery

    Designation MetallicContamination Sensor, MCS13xx O-ring (18.7 x 3.53 NBR 70 Shore) O-ring (25 x 3.53 NBR 70 Shore) Operation and Installation Guide (this document) HYDAC FILTER SYSTEMS GMBH en(us) Page 14 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 15: Checking The Mcs 14Xx Scope Of Delivery

    The following items are supplied: Item Qty. Designation MetallicContamination Sensor, MCS14xx O-ring (25 x 3.53 NBR 70 Shore) Operation and Installation Guide (this document) HYDAC FILTER SYSTEMS GMBH en(us) Page 15 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 16: Checking The Mcs 15Xx Scope Of Delivery

    Designation MetallicContamination Sensor, MCS15xx O-ring (47.22 x 3.53 NBR 70 Shore) O-ring (110.72 x 3.53 NBR 70 Shore) Operation and Installation Guide (this document) HYDAC FILTER SYSTEMS GMBH en(us) Page 16 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 17: Mcs Features

    The output signal at the switching output is always the same and provides no information about the size of the particle. Using the serial interfaces (RS 485 or HSI) makes it possible to evaluate appropriate particle size classes. HYDAC FILTER SYSTEMS GMBH en(us) Page 17 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc...
  • Page 18: Usable Operating Media

    (for example: poly-alpha-olefins PAO and polyglycol, as used in the wind energy industry). ► The media used must be permanently compatible with the MCS sealing material - low-temperature FKM. HYDAC FILTER SYSTEMS GMBH en(us) Page 18 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc...
  • Page 19: Dimensions

    MCS 1000 Series Dimensions Dimensions MCS13xx Flange image SAE 3/4" All dimensions in mm. HYDAC FILTER SYSTEMS GMBH en(us) Page 19 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 20: Mcs13Xx With Ethernet Module

    MCS 1000 Series Dimensions MCS13xx with Ethernet module Flange image SAE 3/4" All dimensions in mm. HYDAC FILTER SYSTEMS GMBH en(us) Page 20 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 21: Mcs13Xx With Flange Adapter Set (Optional Accessories)

    MCS 1000 Series Dimensions MCS13xx with flange adapter set (optional accessories) All dimensions in mm. HYDAC FILTER SYSTEMS GMBH en(us) Page 21 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 22: Mcs14Xx

    MCS 1000 Series Dimensions MCS14xx Flange image SAE 3/4" All dimensions in mm. HYDAC FILTER SYSTEMS GMBH en(us) Page 22 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 23: Mcs14Xx With Ethernet

    MCS 1000 Series Dimensions MCS14xx with Ethernet Flange image SAE 3/4" All dimensions in mm. HYDAC FILTER SYSTEMS GMBH en(us) Page 23 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 24: Mcs14Xx With Flange Adapter Set (Optional Accessories)

    MCS 1000 Series Dimensions MCS14xx with flange adapter set (optional accessories) All dimensions in mm. HYDAC FILTER SYSTEMS GMBH en(us) Page 24 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 25: Mcs15Xx

    MCS 1000 Series Dimensions MCS15xx Flange image SAE 4" All dimensions in mm. HYDAC FILTER SYSTEMS GMBH en(us) Page 25 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 26: Mcs15Xx With Ethernet

    MCS 1000 Series Dimensions MCS15xx with Ethernet Flange image SAE 3/4" All dimensions in mm. HYDAC FILTER SYSTEMS GMBH en(us) Page 26 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 27: Mcs15Xx With Flange Adapter Set (Optional Accessories)

    MCS 1000 Series Dimensions MCS15xx with flange adapter set (optional accessories) All dimensions in mm. HYDAC FILTER SYSTEMS GMBH en(us) Page 27 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 28: Mechanical Connection Types

    The MCS is designed for IP67 according to DIN 40050 / EN 60529 / IEC 529 / VDE 0470. Select between the following mechanical connection types: HYDAC FILTER SYSTEMS GMBH en(us) Page 28 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc...
  • Page 29: Connecting Mcs14Xx Via Flange Adapter Set

    MCS 1000 Series Mechanical connection types Connecting MCS14xx via flange adapter set A flange adapter set is available from HYDAC as an accessory under p/no. 3588249. This flange adapter set makes it possible for you to connect the MCS directly to two pipes or hoses via the thread G1/2".
  • Page 30: Fastening The Mcs On The Underside

    MCS models manufactured in 2012 and following have 4 fixing holes on the underside Use these to secure the MCS Below you will find the corresponding drilling templates for the individual MCS models. HYDAC FILTER SYSTEMS GMBH en(us) Page 30 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc...
  • Page 31: Fastening The Mcs 13Xx

    MCS 1000 Series Fastening the MCS on the underside Fastening the MCS 13xx Fastening the MCS 14xx HYDAC FILTER SYSTEMS GMBH en(us) Page 31 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 32: Fastening The Mcs 15Xx

    MCS 1000 Series Fastening the MCS on the underside Fastening the MCS 15xx HYDAC FILTER SYSTEMS GMBH en(us) Page 32 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 33: Fastening Mcs15Xx Via Angle Fastening Set

    Fastening the MCS on the underside Fastening MCS15xx via angle fastening set An angle fastening set is available as an accessory. HYDAC article no. 3477243. Connecting MCS15xx via pipe adapter set A pipe adapter set is available as an accessory. HYDAC article no. 3435426.
  • Page 34: Connecting Mcs15Xx Via Flange Adapter Plate (Accessories)

    Fastening the MCS on the underside Connecting MCS15xx via flange adapter plate (accessories) A flange adapter set is available as an accessory. HYDAC article no. 3442518. With the flange adapter set SAE4"-SAE1½" (1) you have the opportunity to mount the MCS between the filter unit and the pump. The flange adapter plate offers three ¼"...
  • Page 35: Connecting Mcs15Xx Via Sae 4" Per Iso 6162-1 (4Xm16)

    NOTICE Working overpressure The MCS will be destroyed. ► Note the maximum operating pressure of 20 bar / 290 psi. HYDAC FILTER SYSTEMS GMBH en(us) Page 35 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 36: Flow Rate, Differential Pressure And Viscosity  Characteristics

    40 l/min and for the MCS15xx between 10 and 200 l/min. For flow rates outside these limits, a detection of particles is no longer guaranteed. Q l/min Q l/min HYDAC FILTER SYSTEMS GMBH en(us) Page 36 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc...
  • Page 37 MCS hydraulic installation Q l/min  The diagram shows the resulting differential pressure mbar as a function of the flow rate Q l/min at different viscosities. HYDAC FILTER SYSTEMS GMBH en(us) Page 37 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 38: Electrical Connection Of The Mcs

    Supply voltage 9 ... 36 V DC Switch out 2 (normally open) GND for supply voltage GND switching output HSI (HYDAC Sensor Interface) RS485 + RS485 - Switch out 1 (normally open) The two switching outputs are in each case a passive, n-switching power MOSFET.
  • Page 39: Connection Cable - Assignment / Color Coding

    Our accessories list includes connection cables of various lengths with one connection plug (8-pole, M12x1, according to DIN VDE 0627) and an open end. The color coding of the HYDAC accessory cable ZBE42-xx is listed in the table below: Color...
  • Page 40: Connecting Cable Wires

    Measurement Voltage U at switching output 1/2 for superordinate M1/2 voltage controllers. Signal value Measurement voltage on = high Measurement voltage off = low HYDAC FILTER SYSTEMS GMBH en(us) Page 40 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 41: Using Switching Outputs

    1. The switching output 2 outputs the "Device Ready" signal indicating readiness for use. Particles Switching Output ferromagnetic (Fe) non-ferromagnetic (nFe) Device Ready HYDAC FILTER SYSTEMS GMBH en(us) Page 41 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 42: Switching Logic "Active Low

    ~ 70 seconds is necessary before the first measurement can be made. Example: Operation - 1 particle detected Δt M1/2  70 s HYDAC FILTER SYSTEMS GMBH en(us) Page 42 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 43: Example: Operation - No Particle Detected

    MCS 1000 Series Switching logic "active low" Example: Operation - no particle detected M1/2 Example: Operation - several particles detected Δt Δt Δt M1/2 HYDAC FILTER SYSTEMS GMBH en(us) Page 43 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 44: Switching Logic "Active High

    ~ 70 seconds is necessary before the first measurement can be made. Example: Operation - 1 particle detected Δt M1/2 3 s 70 s HYDAC FILTER SYSTEMS GMBH en(us) Page 44 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 45: Example: Operation - No Particle Detected

    MCS 1000 Series Switching logic "active high" Example: Operation - no particle detected M1/2 Example: Operation - several particles detected Δt Δt Δt M1/2 HYDAC FILTER SYSTEMS GMBH en(us) Page 45 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 46: Switching Output "Device Ready

    ~ 70 seconds is necessary before the signal can be evaluated. After that, the switching output "Device Ready" goes to permanent "low" potential. M1/2  70 s HYDAC FILTER SYSTEMS GMBH en(us) Page 46 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 47: Parameterizing Mcs / Reading Off Measured Values

    Parameterizing MCS / reading off measured Parameterizing MCS / reading off measured values Connecting MCS 1000 with SMU 1200 The MCS 1000 can be connected to the HYDAC SensorMonitoring Unit SMU 1200. The SMU1200 makes it possible to:  set parameters ...
  • Page 48: Connecting Mcs With Csi-D-5 (Condition Sensor Interface)

    With the CSI-D-5 kit you have the opportunity to parameterize the MCS using a PC and to read off online and stored measurement data. Connect the CSI-D-5 kit, HYDAC article no. 3249563, in accordance with the following connection diagram. CSI-D-5 Kit...
  • Page 49: Connecting Mcs To Hmg 3000

    Connect the HMG 3000 to the MCS in accordance with the following connection diagram. ZBE 30-xx ZBE 41 HMG 3000 MCS 1000 You can find more details in the HMG 3000 operating instructions. HYDAC FILTER SYSTEMS GMBH en(us) Page 49 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 50: Evaluating Measurement Results

    Is a fluid filter present that filters out the particles, or are they conveyed through the circuit? Example: Without filtration, an individual particle can be detected several times by the MCS. HYDAC FILTER SYSTEMS GMBH en(us) Page 50 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc...
  • Page 51: Menu Structure

    CYC C CYC D CYC E CYC F STATUS TEMP C TEMP F SWT.OUT FE.NFE ALL.RDY SWT.LOG ACT.HI ACT.LOW SWT.PLS Set value CANCEL SAVE HYDAC FILTER SYSTEMS GMBH en(us) Page 51 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 52: Powerup Menu

    Factory setting: DFAULT - Reset to factory setting Function: Reset to the factory settings You can find the factory setting at the corresponding parameter. HYDAC FILTER SYSTEMS GMBH en(us) Page 52 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 53: Cancel - Cancel Without Saving

    Class A particles (Fe) CYC B: ferromagnetic Class B particles (Fe) CYC C: ferromagnetic Class C particles (Fe) CYC D: non-ferromagnetic Class D particles (nFe) HYDAC FILTER SYSTEMS GMBH en(us) Page 53 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 54: Swt.out - Set Switching Output

    S1 = Ferromagnetic (Fe) S2 = Non-ferromagnetic (nFe) ALL.RDY S1 = ferromagnetic (Fe) and non- ferromagnetic (nFe) S2 = Device Ready Factory setting: FE.NFE HYDAC FILTER SYSTEMS GMBH en(us) Page 54 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 55: Swt.log - Set Logic At The Switching Output

    Setting the pulse length of the switching outputs Parameters: 5 - 200 milliseconds Factory setting: CANCEL - cancel without saving Parameters: none SAVE - Save changes Parameters: none HYDAC FILTER SYSTEMS GMBH en(us) Page 55 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 56: Error Analysis / Remedy

    / grey / gris rosa / pink / rose blau / blue / bleu rot / red / rouge Schirm / Shield / B lindage HYDAC FILTER SYSTEMS GMBH en(us) Page 56 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 57 The MCS is switched Reestablish the off; error in operation operation and voltage / measurement measurement voltage. voltage HYDAC FILTER SYSTEMS GMBH en(us) Page 57 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 58: Error Status - "Active High" And "Active Low

    Perform a reset. Remove the connection cable of the MCS for 10 seconds. Reconnect the connection cable to the MCS. If there is no change in the error status, contact HYDAC. Observe the starting phase of ~ 70 seconds. Error status 1 "active low"...
  • Page 59: Error Status 1 "Active High

    Evaluate the signal duration and the behavior of the two switching outputs S1 and S2 separately. M1/2 Operation voltage Measurement voltage U M1/2 HYDAC FILTER SYSTEMS GMBH en(us) Page 59 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 60: Error Status 2 "Active High

    Measurement voltage U M1/2 Error status - "Device Ready" In the "Device Ready" error status there is a signal change from "low" to "high" M1/2 HYDAC FILTER SYSTEMS GMBH en(us) Page 60 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 61: Servicing The Mcs

    After disassembling the unit and separating the various materials, reuse them or dispose of them properly in accordance with local regulations. HYDAC FILTER SYSTEMS GMBH en(us) Page 61 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc...
  • Page 62: Spare Parts And Accessories

    3588249 MCS15xx pipe adapter set 42L, consisting of: 2x Pipe adapter 42L 2x O-rings 8x Cylinder head screw 8x Washer 8x Spring washer 3435426 HYDAC FILTER SYSTEMS GMBH en(us) Page 62 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 63 Socket plug (female) with 2 m line, ZBE 42-02 3281220 shielded, 8-pole, M12x1 Socket plug (female) with 5 m line, ZBE 42-05 3281239 shielded, 8-pole, M12x1 HYDAC FILTER SYSTEMS GMBH en(us) Page 63 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 64: Mcs Channel Default Settings

    Class E 300 … 400 µm 450 … 600 µm 750 … 1000 µm Class F > 400 µm > 600 µm > 1000 µm HYDAC FILTER SYSTEMS GMBH en(us) Page 64 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 65: Technical Data

    1 x Particle (Fe + nFe) 1 x Device Ready signal Switching output loadable with maximum: 1.5 A; 40 V DC RS485 interface 2 wire, half duplex HYDAC FILTER SYSTEMS GMBH en(us) Page 65 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 66: Detection Limits

    HYDAC SERVICE GMBH Friedrichsthaler Straße 15a , Werk 13 66540 Neunkirchen-Heinitz Germany Telephone: ++49 (0)6897 509 883 Fax: ++49 (0)6897 509 324 E-mail: service@hydac.com HYDAC FILTER SYSTEMS GMBH en(us) Page 66 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 67: Model Code

    = Male connection M 12x1, 8 pole = Male connection M 12x1, 8 pole and Ethernet M 12x1, 4 pole, D coded acc. IEC61076-2-101 Modification number = Standard HYDAC FILTER SYSTEMS GMBH en(us) Page 67 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 68: Examples Of Connection

    / brown / brun R = 1k weiss / white / blanc gelb / yellow / jaune 9...36 V DC grün / green / vert ZBE 42S-xx HYDAC FILTER SYSTEMS GMBH en(us) Page 68 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 69: Using Switching Output 1 And 2

    / red / rouge gelb / yellow / jaune weiss / white / blanc 24 V DC grün / green / vert ZBE 42S-xx HYDAC FILTER SYSTEMS GMBH en(us) Page 69 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 70: Using Switching Output 2

    R = 1k 10 V DC gelb / yellow / jaune ZBE 42S-xx weiss / white / blanc 24 V DC grün / green / vert HYDAC FILTER SYSTEMS GMBH en(us) Page 70 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc 2012-06-15...
  • Page 71: Ec Declaration Of Conformity

    Documentation Representative: Mathias Dieter, Dipl.Kfm. Wolfgang Haering Mr. Günter Harge Registered seat of company: 66280 Sulzbach / Saar - Germany c/o HYDAC International GmbH, Industriegebiet, 66280 Sulzbach / Saar Registry Court: Saarbrücken, HRB 17216 Telephone: ++49 (0) 6897 509 1511...
  • Page 72: Glossary

    February 2010 as an "add on" for condition monitoring systems in wind power plants. The certification was provided by Germanischer Lloyd Industrial Services GmbH. HYDAC FILTER SYSTEMS GMBH en(us) Page 72 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc...
  • Page 73: Basics Of Gl Certification

    GL is one of the leading certification authorities in the wind energy sector, performing tests, certification procedures and approvals for wind power plants and their components. HYDAC FILTER SYSTEMS GMBH en(us) Page 73 / 76 BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc...
  • Page 76 HYDAC FILTER SYSTEMS GMBH Industriegebiet Postfach 1251 66280 Sulzbach / Saar 66273 Sulzbach / Saar Germany Germany Phone: +49 (0) 6897 509 01 Central Fax: +49 (0) 6897 509 846 (Technical Department) Fax: +49 (0) 6897 509 577 (Sales Department) Internet: www.hydac.com...

This manual is also suitable for:

Mcs 13xxMcs 14xxMcs 15xx

Table of Contents