Kubota D1503-M Workshop Manual page 84

Wsm 03-m-e3b series, 03-m-di-e3b series, 03-m-e3bg series
Table of Contents

Advertisement

03-M-E3B, 03-M-DI-E3B, 03-M-E3BG WSM
Blinking Pattern of Glow Lamp
(1-Long and 1-Short)
(1-Long and 2-Short)
(1-Long and 3-Short)
(1-Long and 4-Short)
(1-Long and 5-Short)
(2-Long and 1-Short)
(2-Long and 2-Short)
(2-Long and 4-Short)
(2-Long and 5-Short)
(2-Long and 6-Short)
Cause
Overrunning (more than
115 %)
Low oil pressure
Defect of alternator
Coolant temperature is
abnormal
Emergency stop switch
operated
Abnormality of speed
sensor
Solenoid malfunction
Disconnection of water
temperature sensor
Short circuit of water
temperature sensor
Disconnection of alternator
L Terminal
S-6
DIESEL ENGINE
Refer to Checking
Solenoid
Oil sensor
Alternator
Water temperature sensor
Emergency stop switch
Speed sensor
Solenoid
Water temperature sensor
Water temperature sensor
Alternator L Terminal
W1042224
KiSC issued 07, 2008 A