Remote Management Processor Serial Port Configuration; Using Tcp/Ip Over Ethernet Management Port; Selecting An Ethernet Management Port - HP ProLiant DL140 User Manual

Generation 2 lights-out 100i remote management processor
Hide thumbs Also See for ProLiant DL140:
Table of Contents

Advertisement

8
HP ProLiant DL140 and HP ProLiant DL145 Lights-Out 100i Remote Management
User Guide
5. Press the down arrow key (↓) to scroll to the Serial Port menu. Press the
Enter key to toggle between SIO COM Port and BMC COM Port.
6. Select BMC COM Port.

Remote management processor serial port configuration

1. Power on the server by pressing the power on/off button on the front panel.
2. When POST shows the message ROM-Based Setup, press the F10 key.
If the server has an administrator password configured, the system prompts
you to enter the password. If the server does not have a password configured,
the main screen of the BIOS Setup Utility appears.
3. Press the right arrow (→) key to navigate to the Advanced menu.
4. Press the down arrow (↓) key to scroll to the Console Redirection menu.
5. Press the Enter key to toggle between Enabled and Disabled. Select
Enabled.
6. Review the serial port settings, and be sure the settings match the serial port
communications software settings used to connect to the remote management
processor.
7. Press the Esc key to return to the previous screen, or press the F10 key to
save the changes and exit Setup.

Using TCP/IP over Ethernet management port

The remote management processor LAN port can be accessed from two different
Ethernet ports: the dedicated 10\100 LOi00i management port, or through a side-
band connection with the second LOM (NIC2).

Selecting an Ethernet management port

To select either the LO100i or side-band connection:
1. Power on the server by pressing the power on/off button on the front panel.