TABLE 5-12
Argument
-P,--fcportspeed
{auto | 1 | 2}
-F,--fctopology
{auto | loop |
fabric_p2p}
-d,--description text
5.3.6
Managing Storage Pools
Use the sscs commands described in these subsections to create and manage
storage pools on the Sun StorEdge 6020 arrays. You can create and delete storage
pools, place the storage in the pools online or offline, and configure related pool
settings.
5.3.6.1
Creating a Storage Pool
Use this command to create a storage pool. After creating the pool, use the create
volume subcommand to specify volumes and the add subcommand to add storage
volumes to the pool. The sscs create pool command-line syntax is shown
below.
# sscs create -a array-name -t trayid -d number -r {0 | 1 | 5} -s {0 | 1}
TABLE 5-13
TABLE 5-13
Argument
-a,--array array-name
-t,--trayid trayid
-d,--drives num
5-20
Sun StorEdge 6320 System 1.0 Reference and Service Manual • May 2003
sscs modify array Command-Line Arguments
pool pool-name
describes the arguments associated with the create pool subcommand.
sscs create pool Command-Line Arguments
Description
Specify the Fibre Channel port speed: auto, 1 Gbyte, or 2
Gbyte.
Specify the Fibre Channel topology for the array:
auto, loop (arbitrated loop), or fabric_p2p (point-to-point).
Type text describing the array, up to 16 characters long
Description
Specifies an array-name up to 40 characters long.
Specifies a disk tray identification name trayid up to 24
characters long.
Specifies the number of drives in the pool.