Electrical Parts - Carrier 38MAQB12-1 Service Manual

38maq series outdoor unit single zone ductless system sizes 09 to 30
Table of Contents

Advertisement

DISASSEMBLY INSTRUCTIONS SIZES 09−12 (CONT)
3
Electrical
parts
How to remove the

electrical parts.

1) Complete the
steps in sections 1
and 2 then remove
the 3 connectors
for the compressor
and the electrical
heaters.
2) Release the
reactor connector.
3) Pull out the two
blue wires
connected to the
four way valve.
4) Remove the
compressor top
temp. sensor
connectors,
condenser coil
temp. sensor (T3),
outdoor ambient
temp. sensor (T4)
and the discharge
temp. sensor (T5).
Compressor connector
Two blue wires of four way valve
Four temp. sensor connectors.
55
Reactor connector

Hide quick links: