Ipm Continuity Check; Pressure On Service Port; Heating Charts - Carrier 38MAQB12-1 Service Manual

38maq series outdoor unit single zone ductless system sizes 09 to 30
Table of Contents

Advertisement

IPM Continuity Check

Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital tester to measure
the resistance between P and UVWN; UVW and N.
DIGITAL TESTER
(+)Red
(-)Black
N
U
P
V
W

Pressure on Service Port

Heating Charts

(
)
ODT/IDT
° F
° C
BAR
55
BAR
65
BAR
75
(
)
ODT/IDT
° F
° C
PSI
55
PSI
65
PSI
75
(
)
ODT/IDT
° F
° C
MPA
55
MPA
65
MPA
75
Table 25—Digital Tester
NORMAL RESISTANCE
VALUE
(Several MΩ)
Table 26—Heating Chart
57/53
47/43
(13.89/11.67)
(8.33/6.11)
30.3
28.5
32.5
30.0
33.8
31.5
Table 27—Heating Chart
57/53
47/43
(13.89/11.67)
(8.33/6.11)
439
413
471
435
489
457
Table 28—Heating Chart
57/53
47/43
(13.89/11.67)
(8.33/6.11)
3.03
2.85
3.25
3.00
3.38
3.15
Fig. 43 – Heating Chart
DIGITAL TESTER
(+)Red
(-)Black
U
V
N
W
(+)Red
37/33
27/33
(2.78/0.56)
(-2.78/-5)
25.3
22.8
26.6
25.4
27.8
26.3
37/33
27/33
(2.78/0.56)
(-2.78/-5)
367
330
386
368
403
381
37/33
27/33
(2.78/0.56)
(-2.78/-5)
2.53
2.28
2.66
2.54
2.78
2.63
50
NORMAL RESISTANCE
VALUE
(Several MΩ)
17/13
(-8.33/-10.56)
20.8
23.3
24.9
17/13
(-8.33/-10.56)
302
339
362
17/13
(-8.33/-10.56)
2.08
2.33
2.49

Hide quick links: