IPM Continuity Check
Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital tester to measure
the resistance between P and UVWN; UVW and N.
DIGITAL TESTER
(+)Red
(-)Black
N
U
P
V
W
Pressure on Service Port
Heating Charts
(
)
ODT/IDT
° F
° C
BAR
55
BAR
65
BAR
75
(
)
ODT/IDT
° F
° C
PSI
55
PSI
65
PSI
75
(
)
ODT/IDT
° F
° C
MPA
55
MPA
65
MPA
75
Table 25—Digital Tester
NORMAL RESISTANCE
VALUE
∞
(Several MΩ)
Table 26—Heating Chart
57/53
47/43
(13.89/11.67)
(8.33/6.11)
30.3
28.5
32.5
30.0
33.8
31.5
Table 27—Heating Chart
57/53
47/43
(13.89/11.67)
(8.33/6.11)
439
413
471
435
489
457
Table 28—Heating Chart
57/53
47/43
(13.89/11.67)
(8.33/6.11)
3.03
2.85
3.25
3.00
3.38
3.15
Fig. 43 – Heating Chart
DIGITAL TESTER
(+)Red
(-)Black
U
V
N
W
(+)Red
37/33
27/33
(2.78/0.56)
(-2.78/-5)
25.3
22.8
26.6
25.4
27.8
26.3
37/33
27/33
(2.78/0.56)
(-2.78/-5)
367
330
386
368
403
381
37/33
27/33
(2.78/0.56)
(-2.78/-5)
2.53
2.28
2.66
2.54
2.78
2.63
50
NORMAL RESISTANCE
VALUE
∞
(Several MΩ)
17/13
(-8.33/-10.56)
20.8
23.3
24.9
17/13
(-8.33/-10.56)
302
339
362
17/13
(-8.33/-10.56)
2.08
2.33
2.49