GE T35 Instruction Manual page 259

Transformer management relay
Hide thumbs Also See for T35:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 8 of 32)
ADDR
REGISTER NAME
350C
RTD Input 29 Value
350D
RTD Input 30 Value
350E
RTD Input 31 Value
350F
RTD Input 32 Value
3510
RTD Input 33 Value
3511
RTD Input 34 Value
3512
RTD Input 35 Value
3513
RTD Input 36 Value
3514
RTD Input 37 Value
3515
RTD Input 38 Value
3516
RTD Input 39 Value
3517
RTD Input 40 Value
3518
RTD Input 41 Value
3519
RTD Input 42 Value
351A
RTD Input 43 Value
351B
RTD Input 44 Value
351C
RTD Input 45 Value
351D
RTD Input 46 Value
351E
RTD Input 47 Value
351F
RTD Input 48 Value
Expanded Direct Input/Output Status (Read Only)
3560
Direct Device States, one per register (8 items)
3570
Direct Input States, one per register (96 items)
Passwords (Read/Write Command)
4000
Command Password Setting
Passwords (Read/Write Setting)
4002
Setting Password Setting
Passwords (Read/Write)
4008
Command Password Entry
400A
Setting Password Entry
Passwords (Read Only)
4010
Command Password Status
4011
Setting Password Status
User Display Invoke (Read/Write Setting)
4040
Invoke and Scroll Through User Display Menu Operand
LED Test (Read/Write Setting)
4048
LED Test Function
4049
LED Test Control
Preferences (Read/Write Setting)
404F
Language
4050
Flash Message Time
4051
Default Message Timeout
4052
Default Message Intensity
4053
Screen Saver Feature
4054
Screen Saver Wait Time
4055
Current Cutoff Level
4056
Voltage Cutoff Level
Communications (Read/Write Setting)
407E
COM1 minimum response time
407F
COM2 minimum response time
4080
Modbus Slave Address
4083
RS485 Com1 Baud Rate
4084
RS485 Com1 Parity
4085
RS485 Com2 Baud Rate
GE Multilin
RANGE
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 65535
0 to 1
0 to 65535
0 to 3
0.5 to 10
10 to 900
0 to 3
0 to 1
1 to 65535
0.002 to 0.02
0.1 to 1
0 to 1000
0 to 1000
1 to 254
0 to 11
0 to 2
0 to 11
T35 Transformer Management Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
---
1
F155
---
1
F108
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F102
---
1
F102
---
1
F300
---
1
F102
---
1
F300
---
1
F531
s
0.1
F001
s
1
F001
---
1
F101
---
1
F102
min
1
F001
pu
0.001
F001
V
0.1
F001
ms
10
F001
ms
10
F001
---
1
F001
---
1
F112
---
1
F113
---
1
F112
DEFAULT
0
0
0
0
0
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (Offline)
0 (Off)
0
0
0
0
0 (Disabled)
0 (Disabled)
0
0 (Disabled)
0
0 (English)
10
300
0 (25%)
0 (Disabled)
30
20
10
0
0
254
8 (115200)
0 (None)
8 (115200)
B-15