Checking The Solenoid Valve; Checking The Start Detection System; Electrical Check - Stihl FS 460 C Technical Information

Clearing saw, series 4147
Table of Contents

Advertisement

Technical Information 40.2010
9.5

Checking the solenoid valve

Measure resistance
.
Move choke lever to position F
.
Connect M-Tronic test lead 5910 840 0903 to
the diagnostic jack, see b 9.4
.
Measure resistance between the plugs of the
M-Tronic test lead
Target value: between 28 and 42 ohms
If the target value is not attained, check electrical
leads for interruption, short to voltage and short to
ground see b 9.7.3.
TI_40_2010_13_01_02.fm
9.6

Checking the start detection system

.
Remove the filter cover
.
Remove starter
.
Remove shroud
9.6.1
Mechanical check
.
Set choke lever to position } – the cam (1)
must actuate the pin (2) of the micro switch (3)
9.6.2

Electrical check

1
2
.
Disconnect the plug (1) from the solenoid (2)