Whirlpool R1011 Installation Instructions And Use & Care Manual page 7

Table of Contents

Advertisement

Sprang
grounding
type wall
receptacle
230 and 230/208 volt models
with amperes up through 24.0
Receptacle
wiring
Receptacle wiring should be a minimum of
10 gauge. Use copper wire only. It is the respon-
sibility of the consumer to provide proper and
adequate receptacle wiring, installed by a
qualified electrician. Observe National Electrical
Code and all local governing codes and ordi-
nances.
Electrical
requirements
A 230 volt (207 min., 253 max.), 60 Hz, AC only,
30 ampere (cartridge type) fused electrical supply
is required (time delay fuse or time delay circuit
breaker required). It is required
that a separate
circuit, serving only this appliance,
be provided.
OR
A 230/206 volt (197.6 min., 253 max.), 60 Hz, AC
only, 30 ampere (cartridge type) fused electrical
supply is required (time delay fuse or time delay
circuit breaker required). It is required
that a
separate circuit, serving only this appliance,
be
provided.
Electrical
connection:
Electrical ground is required on this appliance.
Recommended
grounding
method
For your personal safety, this appliance must be
grounded. This air conditioner
is equipped with a
power supply cord having a 3-prong grounding
prong. To minimize possible shock hazard, the
cord must be plugged into a mating 3-prong
grounding type wall receptacle, grounded in
accordance
with the National Electrical Code and
local codes and ordinances.
If a mating wall
receptacle
is not available,
it is the responsibility
of the customer to have a properly grounded
3-prong wall receptacle
installed by a qualified
electrician.
Power
WJdp'Y