Page 1
40 insert stove is exempt for use in smoke control areas when burning dry wood www.heta.dk Danish DesiGn . Danish QUality . Danish ProDUCtion...
Page 2
Signed on behalf the manufacturer of: ____________________________________ Lemvig 18-08-2016. Lars Kirk HOD _________________________________________________________________________________________ In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid. Heta A/S, Jupitervej 22, DK - 7620 Lemvig, Tlf.: +45 96630600, www.heta.dk Page 1 of 1...
Heta stove. Especially if you follow the following advice and instructions. Inspire 40 wood stove insert is approved according to EN 13229, NS 3058 and 3059. These approvals, means that the wood stove insert meets a variety of specifications and requirements, ensuring it is made of quality materials, minimum environmental impact and that it has an optimum fuel economy.
It is important that upon receipt check your Heta product completely and report any damage or defects to your dealer. The packaging must be disposed of as follows: Wood is untreated and able to burn in the stove.
Page 5
Instruction manual with mounting tool 1013-0864 Heta glove Door handle 0016-0031 Data plate Ash pan handle 8150-0000-GB DOP-Inspire 40 Insert-2215-2016 1020-0001 Heta A/S Jupitervej 22 7620 Lemvig Denmark 2016 Production year: DS/EN 13229/A2:2004/NS 3058/3059 Product description: Serial No: Inspire 40 Indsats...
1.2 first firing The use of lighter fluid, oils or any liquid fuels is strictly forbidden Heta wood stoves are, treated with a heat-resi- from use in a wood stove. stant coating, which hardens at a temperature of about 250° C. This curing process will cause...
1.6 emptying the ash By using the shaker grate, it rotates back and forth so the ash falls through the holes and into the embers with the majority of them to the front. Place pieces of wood equivalent to about 1 kg on top of the embers perpendicular to the door.
Good draft occurs when: Minimum chimney draft for Inspire 40 insert is 11 pascal. It is the draft that the stove has been • The difference in temperature in the chimney tested and approved on. The minimum draft is...
1.10 fuel almost the same heating value per kg, which is about 5.27 kW/hour for absolute dry wood. Your new stove is EN approved for firing with Wood with a moistness of 18% has a efficiency wood fuel. You must therefore only burn clean, of about 4.18 kW / hour per kg, and one litre dry wood in your stove.
1.13 troubleshooting table Fault Cause Troubleshooting Solution Inadequate chimney draft. Lighting problems. When the You can test using a lighter whether Improve the chimney. The chimney only has stove is cold, smoke seeps flame is drawn into the combustion sufficient draft when it is hot. into the room.
1.14 Maintenance 1.15 Cleaning the glass Incorrect firing, for example using wet wood, The surface of the stove is treated with a heat- can result in the viewing window becoming resistant paint. The stove should be cleaned covered in soot. This soot can be easily and with a damp cloth.
1.17 Cleaning after sweeping or before replacing vermiculite stones Note: it may be necessary to clean/vaccum the holes and air ducts behind the rear stone Removal sequence of stones. Replace in reverse order. Starting with Fig. 6.
The nominal output is the output to which the stove has been tested. The test was carried out with the combustion air 80%. 1.21 Guarantee Heta wood stoves, subjected to a strict quality Should you have cause to make a complaint, control during production and before delivery to please quote our invoice no.
This is to avoid damage to the masonry/ The Inspire 40 insert can be installed with a ho- wall when the stove expands when in use. risontal straight back outlet. Maximum length of the pipe should be 500 mm with a 5”...
Joins bet- The Inspire 40 has a nominal output of less than ween brickwork, the thimble and flue gas pipe 5kW and does not need additional ventilation in...
Page 18
The Building materials that are used in safety test and shown in illustrations on this page, with No. 8. has a thermal conductivity of max. (= <0.36 W (m * K) 7. Min. 160 mm from top edge of convection 1.
2.6 installation of the stove - 2 x M5x10 0008-0005 Attaching the door handle 0016-0031 4 x M10x16 0008-1201 Flue outlet straight up. 2.7 Change to 45 flue outlet...
Flat wall model frame nr. 2110-0007 Hidden wall model frame nr. 2110-0008 Minimum dimensions, hole in brick wall: Inspire 40 Classic floor model, Flat floor- and wall model 22” x 16” x 13,5” 560 x 406 x 340 mm Inspire 40 Hidden wall model 22”...
2.9 fitting the convection case Classic and flat floor model Classic floor model A = 7 mm Flat floor model A = 39 mm Flat and hidden wall model Flat wall model A = 39 mm Hidden wall model A = 47 mm For all four models.
2 x M6x25 0008-1115 - For flue outlet installation 45° backwards, turn the flue pipe connector 180°. 2.13 Mounting the frame Flat wall model Classic floor model A = 7 mm Flat floor model A = 39 mm Flat wall model A = 39 mm Hidden wall model A = 47 mm...
Page 24
Hidden wall model 5 mm Classic floor model, flat floor- and wall model: The frame front must be flush with the front of the door. Hidden wall model. See fig. 6.
Page 25
Classic floor model Flat floor model Flat wall model Hidden wall model...
3. Connecting external air supply from behind 1511-0030 If rear outdoor air connection purchased, 1511-0030 must be installed before inserting the stove. 4. Connecting external air supply from below 1020-0124...
Page 27
1015-0065 If below outdoor air connection purchased, must be installed before inserting 1015-0065 the stove. 1020-0125 2 x 1022-5022 Check that the air regulator moves freely.
”unauthorised volved administrations. fuel” for use within a smoke control area unless The Inspire 40 have all been recommended as it is used in an ”exempt” appliance (”exempted” suitable for use in smoke control areas when from the controls which generally apply in the burning dry wood logs.
Need help?