Valve Replacement - Regency liberty LRI6E Owners & Installation Manual

Gas insert
Hide thumbs Also See for liberty LRI6E:
Table of Contents

Advertisement

VALVE REPLACEMENT

Before you begin:
* Shut off the gas supply to the unit.
Disconnect all electrical supply to the unit.
Always let the appliance cool to room temperature before servicing.
Remove unit flue collars.
1) Remove the Left Control Panel Cover.
2) Disconnect 3 wires (EV1, EV2 and ground) leading to the valve as
shown below.
3) Disconnect the Pressure Regulator cable.
regulator cable
4) Disconnect the Gas Orifice supply line from the outlet of the Gas Valve.
2
1
Pressure
5) Disconnect the Pilot Supply Line from the Gas Valve
6) Disconnect the Gas Supply Line from the On/Off Safety Shut off Valve.
3
7) Remove both Screws that secure the Gas Valve Mounting brackets, both
sides.
maintenance
LRI6E / HRI6E Direct Vent Gas Insert
|
47
| 47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Horizon hri6e

Table of Contents