4. Pressing down on the upper part of the Guide plate with your fingers at the
two positions shown and then rotate the plate toward you to remove it.
Pad ASSY
Guide plate
5. Hold and rotate the bail of the Pick roller unit upward to release the lock.
Brake roller
Bail
66
3.5 Cleaning the Discharge Brush