Displaying And Maintaining Bfd - HP VSR1000 High Availability Configuration Manual

Virtual services router
Table of Contents

Advertisement

Step
5.
Configure the multi-hop
detection time multiplier.
6.
Configure the minimum
interval for receiving multi-hop
BFD control packets.
7.
Configure the minimum
interval for transmitting
multi-hop BFD control packets.

Displaying and maintaining BFD

Execute the display command in any view and the reset command in user view.
Task
Display BFD session information.
Clear BFD session statistics.
Command
bfd multi-hop detect-multiplier
value
bfd multi-hop min-receive-interval
value
bfd multi-hop
min-transmit-interval value
Command
display bfd session [ discriminator value | verbose ]
reset bfd session statistics
53
Remarks
The default setting is 5.
By default, the minimum interval for
receiving multi-hop BFD control
packets is 500 milliseconds.
By default, the minimum interval for
transmitting multi-hop BFD control
packets is 500 milliseconds.