Iridium Communications, Inc.
Iridium 9523 Product Developers' Guide
Revision 2.6
Note: several GSM standard facility codes including the following are NOT supported:
"OI"
BOIC (Bar Outgoing International Calls) (refer GSM 02.88 [4] clause 1). All Iridium calls
are International, so this facility should not be exercised by a user interface.
"OX"
BOIC-exHC (Bar Outgoing International Calls except to Home Country) (refer GSM 02.88
[4] clause 1). All Iridium calls are International, so this facility should not be exercised by
a user interface.
"IR"
BIC-Roam (Bar Incoming Calls when Roaming outside the home country) (refer GSM
02.88 [4] clause 2). In Iridium it is not possible to roam (there is only one "home country"),
so this facility should not be exercised by a user interface.
"AG"
All outGoing barring services (refer GSM 02.30 [5]) (applicable only for <mode>=0). This
subgroup of services cannot be addressed; the user interface should just use "AB".
"AC"
All inComing barring services (refer GSM 02.30 [5]) (applicable only for <mode>=0). This
subgroup of services cannot be addressed; the user interface should just use "AB".
<mode>:
0
Disable (Deactivate)
1
Enable (Activate)
<passwd>: string type, enclosed by " "; for example, "1234".
Note: Factory default SIM card PIN Code is "1111"
Note: Factory default Phone Unlock Code is "1234"
<classx> is a sum of integers each representing a class of information:
1
voice
2
data
4
fax
This parameter defaults to 7, equal to all classes, but the Iridium 9523 only supports Voice Call
Barring so this is illegal. Therefore in practice the FA must supply <classx>=1 when querying or
changing the status of any Call Barring facility. When querying (<mode>=2), <passwd> is
irrelevant and should be supplied as "" in order to allow the <classx>=1 parameter to be supplied.
For facilities "CS", "SC"and "FD", the <passwd> and <classx> parameters are not relevant and
will be ignored if supplied.
Test Command: +CLCK=?
Test command returns the facility values supported by the phone. The response is in the form:
+CLCK:(list of supported <fac>s)
Note: Only "CS" will appear as a supported value if there is no SIM card in the device.
Note: +CLCK is closely related to +CPIN and +CPWD. See these commands for additional information.
5.7.118 +CPWD - Change Password
Exec Command: +CPWD=<fac>,<oldpwd>,<newpwd>
This command sets a new password for the facility lock function defined by the AT command Facility Lock
+CLCK . The following parameter values are currently supported:
<fac>:
"CS"
CNTRL Surface (Phone Unlock Code)
Iridium Communications, Inc.
Proprietary & Confidential Information
Only
Information Contained in this Guide
is Subject to Change Without Notice
Page 91 of 115
Distribution of Guide Restricted
to Product Developers