Cpwd - Change Password - Iridium 9523 Developer's Manual

Hide thumbs Also See for 9523:
Table of Contents

Advertisement

Iridium Communications, Inc.
Iridium 9523 Product Developers' Guide
Revision 2.6
Note: several GSM standard facility codes including the following are NOT supported:
"OI"
BOIC (Bar Outgoing International Calls) (refer GSM 02.88 [4] clause 1). All Iridium calls
are International, so this facility should not be exercised by a user interface.
"OX"
BOIC-exHC (Bar Outgoing International Calls except to Home Country) (refer GSM 02.88
[4] clause 1). All Iridium calls are International, so this facility should not be exercised by
a user interface.
"IR"
BIC-Roam (Bar Incoming Calls when Roaming outside the home country) (refer GSM
02.88 [4] clause 2). In Iridium it is not possible to roam (there is only one "home country"),
so this facility should not be exercised by a user interface.
"AG"
All outGoing barring services (refer GSM 02.30 [5]) (applicable only for <mode>=0). This
subgroup of services cannot be addressed; the user interface should just use "AB".
"AC"
All inComing barring services (refer GSM 02.30 [5]) (applicable only for <mode>=0). This
subgroup of services cannot be addressed; the user interface should just use "AB".
<mode>:
0
Disable (Deactivate)
1
Enable (Activate)
<passwd>: string type, enclosed by " "; for example, "1234".
Note: Factory default SIM card PIN Code is "1111"
Note: Factory default Phone Unlock Code is "1234"
<classx> is a sum of integers each representing a class of information:
1
voice
2
data
4
fax
This parameter defaults to 7, equal to all classes, but the Iridium 9523 only supports Voice Call
Barring so this is illegal. Therefore in practice the FA must supply <classx>=1 when querying or
changing the status of any Call Barring facility. When querying (<mode>=2), <passwd> is
irrelevant and should be supplied as "" in order to allow the <classx>=1 parameter to be supplied.
For facilities "CS", "SC"and "FD", the <passwd> and <classx> parameters are not relevant and
will be ignored if supplied.
Test Command: +CLCK=?
Test command returns the facility values supported by the phone. The response is in the form:
+CLCK:(list of supported <fac>s)
Note: Only "CS" will appear as a supported value if there is no SIM card in the device.
Note: +CLCK is closely related to +CPIN and +CPWD. See these commands for additional information.

5.7.118 +CPWD - Change Password

Exec Command: +CPWD=<fac>,<oldpwd>,<newpwd>
This command sets a new password for the facility lock function defined by the AT command Facility Lock
+CLCK . The following parameter values are currently supported:
<fac>:
"CS"
CNTRL Surface (Phone Unlock Code)
Iridium Communications, Inc.
Proprietary & Confidential Information
Only
Information Contained in this Guide
is Subject to Change Without Notice
Page 91 of 115
Distribution of Guide Restricted
to Product Developers

Advertisement

Table of Contents
loading

Table of Contents