9. Unscrew the conversion plug on the front of the valve using a ¼" flat-head screwdriver (see pictures
below). Carefully unsnap the plastic cap on the inward end of the conversion plug. Rotate the plug
180° and re-attach it to the conversion plug. Screw the conversion plug back into the gas control
valve – do not overtighten the conversion plug – it is not a gas seal.
Conversion Plug
Carefully unsnap the plastic cap on the inward end of the conversion plug. Rotate the plug 180° and re-
attach it to the conversion plug. Screw the conversion plug back into the gas control valve – do not
overtighten the conversion plug.
Note Position of Notch
10. Replace the firebox components.
11. Restore the appliance to the correct configuration. Make the gas line connection, bleed the gas line
(if applicable), start the heater and thoroughly leak-test all gas connections and the gas control valve.
© Travis Industries
NG = Notch Out
LP = Notch In
(
for qualified installers only)