Download Print this page

Sony CCU-700A Operation Manual page 9

Camera control unit
Hide thumbs Also See for CCU-700A:

Advertisement

@¡ INTERCOM/TALLY/PGM (program audio)
connector (19-pin)
Supplies and accepts intercom, tally, and program
audio signals. Connect to the corresponding
connector on the intercom system.
@™ RTS (RTS intercom) connectors (XLR 3-pin)
Connect an RTS intercom system.
@£ INTERCOM REMOTE connector (D-sub
25-pin)
Connect an external controller to control intercom
muting, producer-line interruption, and engineer-
line interruption.
This connector outputs the red tally, green tally,
tally and call signals, and camera number.
@¢ MIC REMOTE (microphone remote control)
connector (D-sub 15-pin)
Connect an external control unit such as an audio
mixer. You can set the microphone input level of
the video camera to –60, –50, –40, –30, or –20 dB
with the connected unit. Set the microphone
volume to the level suitable for shooting
conditions. You can also set the microphone input
level with the switch on the internal board of this
unit.
This connector outputs the red tally, and green
tally signals.
For details on setting the microphone input level with
the internal switch, refer to the System Manual.
@∞ Voltage selector (only for the CCU-700AP)
The operating voltage of the CCU-700AP is set to
220 to 240 V AC at the factory. If the voltage of
your local power line is different, change the
setting of the voltage selector.
For changing the voltage selector setting, contact
qualified Sony service personnel.