Verifying NPV
vfc3/1
Total number of flogi = 4
For each server interface, the External Interface value displays the assigned NP uplink.
Note
To display the status of the server interfaces and the NP uplink interfaces, enter the show npv status command:
switch# show npv status
npiv is enabled
External Interfaces:
====================
Interface: fc2/1, VSAN: 1, FCID: 0x1c0000, State: Up
Interface: fc2/2, VSAN: 1, FCID: 0x040000, State: Up
Interface: fc2/3, VSAN: 1, FCID: 0x260000, State: Up
Interface: fc2/4, VSAN: 1, FCID: 0x1a0000, State: Up
Number of External Interfaces: 4
Server Interfaces:
==================
Interface: vfc3/1, VSAN: 1, NPIV: No, State: Up
Number of Server Interfaces: 1
Note
To view fcns database entries for NPV edge switches, you must enter the show fcns database command
on the core switch.
To view all the NPV edge switches, enter the show fcns database command on the core switch:
core-switch# show fcns database
For additional details (such as IP addresses, switch names, interface names) about the NPV edge switches
that you see in the show fcns database output, enter the show fcns database detail command on the core
switch:
core-switch# show fcns database detail

Verifying NPV Traffic Management

To display the NPV traffic map, enter the show npv traffic-map command.
switch# show npv traffic-map
NPV Traffic Map Information:
----------------------------------------
Server-If
----------------------------------------
fc1/3
fc1/5
----------------------------------------
To display the NPV internal traffic details, enter the show npv internal info traffic-map command.
To display the disruptive load-balancing status, enter the show npv status command:
switch# show npv status
npiv is enabled
disruptive load balancing is enabled
External Interfaces:
====================
Interface: fc2/1, VSAN: 2, FCID: 0x1c0000, State: Up
...
Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide