Verifying Npv; Verifying Npv Examples - Cisco Nexus 5000 Series Configuration Manual

Nx-os san switching configuration guide
Hide thumbs Also See for Nexus 5000 Series:
Table of Contents

Advertisement

Configuring N Port Virtualization
To enable disruptive load balancing, perform this task:
SUMMARY STEPS
1. switch# configure terminal
2. switch(config)# npv auto-load-balance disruptive
3. switch (config)# no npv auto-load-balance disruptive
DETAILED STEPS
Command or Action
Step 1
switch# configure terminal
Step 2
switch(config)# npv auto-load-balance disruptive
Step 3
switch (config)# no npv auto-load-balance disruptive

Verifying NPV

To display information about NPV, perform the following task:
SUMMARY STEPS
1. switch# show npv flogi-table [all]
DETAILED STEPS
Command or Action
Step 1
switch# show npv flogi-table [all]

Verifying NPV Examples

To display a list of devices on a server interface and their assigned NP uplinks, enter the show npv flogi-table
command on the Cisco Nexus 5000 Series switch:
switch# show npv flogi-table
--------------------------------------------------------------------------------
SERVER
INTERFACE VSAN FCID
--------------------------------------------------------------------------------
vfc3/1
vfc3/1
vfc3/1
OL-xxxxx-xx
PORT NAME
1
0xee0008 10:00:00:00:c9:60:e4:9a 20:00:00:00:c9:60:e4:9a fc2/1
1
0xee0009 20:00:00:00:0a:00:00:01 20:00:00:00:c9:60:e4:9a fc2/2
1
0xee000a 20:00:00:00:0a:00:00:02 20:00:00:00:c9:60:e4:9a fc2/3
Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide
Purpose
Enters configuration mode on the NPV.
Enables disruptive load balancing on the switch.
Disables disruptive load balancing on the switch.
Purpose
Displays the NPV configuration.
NODE NAME
Verifying NPV
EXTERNAL
INTERFACE
57