I N S T R U C T I O N
M A N U A L
TRANSCEIVER/ REFLECTOR:
Enclosure/Power Requirements
Path Length
Optical System
Ambient Light Immunity
Reflector
Alignment Verification
SOURCE Aging Compensation
SOURCE Expected Life
Ambient Temperature Limits
Process Gas
Mounting Flanges
DESIGN AND PERFORMANCE:
Peak and Mean Spectral Response
Angle of View
Angle of Projection
Calibration Error
Response time
Zero Drift
Calibration Drift
Operational Period
R E V
4 . 2
NEMA 4X. Power 120 or 240VAC +/- 10%, 50/60Hz. 65va for
transceiver, 65va for Service module.
2 to 50 feet (0.6 to 4.6 15.2 meters)
Double Pass with Wide band source, Electronic Modulation. USDEP
40 CFR 60 appendix B, PS-1 and ASTM D 6216 specifications.
Wide band source, Electronic Modulation. USDEP 40 CFR 60
appendix B, PS-1 and ASTM D 6216 specifications.
Type 1 (plastic) reflector assembly, long path Glass.
Built-in through-the-lens system standard
Automatic
70,000 hours (Field proven for > 8 years)
o
-40 to +130
F (-40 to +54
o
Up to 750
F (400
3 inch IPS, 150# flange (other sizes available)
Photopic; 515 to 585 nm, less than 10% of peak response outside
the desired 400 to 700 nm region. USDEP 40 CFR 60 appendix B,
PS-1 and ASTM D 6216 specifications.
o
<4.0
from optical axis
o
< 4.0
from optical axis
< +2% of full scale
< 10 second
< 1% (24 hours)
< 1% (24 hours)
6 Months
o
C)
o
C) higher available contact the factory.