The "READY" indicators will continue to flash until the heater unit is full and has self -
calibrated to the correct boiling temperature. At this point, the "READY" indicators will
stop flashing and remain illuminated. If the calibration procedure is interrupted the light
will continue to flash until the unit has calibrated. Wait until the ready indicators remain
illuminated before use.
Do not draw any water off during the self - commissioning mode.
10.8
The Aquatap heater unit and dispenser tap should now be flushed to remove any
installation residues and pasteurise the surfaces in contact with the water.
10.9
To dispense hot water press the button marked "SAFETY" on the dispenser tap (the
safety button must be released before the dispense button can be activated. You have a
5 second window in which to start dispensing) followed by the HOT water button (red).
The hot water dispensing button must remain pressed for the water to flow. If released,
it will be necessary to press the "SAFETY" button again before more water can be dis
pensed. To dispense chilled/ambient water, press the CHILLED/AMBIENT button (blue).
The safety button does not have to be pressed for chilled/ambient water. If both the
CHILLED/AMBIENT and HOT water buttons are
pressed simultaneously the CHILLED/
AMBIENT button will always take preference.
10.10 Following flushing, it is recommended that the
power is switched off and the Aquatap casing
removed to check for any internal leaks.
Always disconnect the electrical supply
before removing the cover.
If there are no leaks evident, replace and secure
the front casing. Switch on the electrical supply.
The "READY" indicator will illuminate on the Aquatap unit and
dispenser tap. The "READY" indicators will flash for a short time as the unit re-calibrates
and checks the correct fill level. When the "READY" indicators stop flashing and remain
solid, the Aquatap unit will be ready for use.
10.11 After commissioning, the following should be explained to the user:
Correct operation of the Aquatap water heater and dispensing tap.
Advise the position of the water and electrical isolation points.
How to identify if there is a malfunction of the unit. Explain that in the event of a
malfunction of the unit or dispenser tap, any maintenance or servicing must only
be carried out by a competent installer.
Explain the necessity for regular maintenance of the system to ensure continued
safe and efficient operation.
Draw the users attention to section 11.0, page 19 of these instructions which
detail the correct use of the system.