    Contents 1. Introduction ..........3 6. Installation ............8 1.1 General ..........3 6.1 General ..........8 1.2 Symbols used .........3 6.2 Water connections ........8 1.3 Abbreviations ..........3 6.3 Electrical connections ......9 1.4 Liabilities ..........3 7. Commissioning ..........10 2. Safety ............4 7.1 General ..........10 2.1 General safety warnings ......4 7.2 Checklist before commissioning .....10 2.2 Recommendations .........4...
  • Page 3: Introduction

    1.4 Liabilities 1. Introduction Manufacturer’s liability Our products are manufactured in compliance with 1.1 General the requirements of the various applicable European Directives. The following instructions are offered as a guide to the user and installer. This product complies with the requirements of the CE marking directive.
  • Page 4: Safety

    2.3 Specific safety instructions 2. Safety WARNING 2.1 General safety warnings DO NOT operate the product if: DANGER Water ceases to flow during use. Water has entered inside the This product is unvented and as such product because of an incorrectly becomes pressurised when in operation.
  • Page 5: Technical Specification

    3. Technical specification 3.1 Technical data 3kW@240V~/2.75kW@230V~ Electrical rating 4.5kW@240V~/4.1kW@230V~ Capacities 10 or 15 litres Weight (full) 10 litre - 16.9kg 15 litre - 23.8kg Rated pressure 0.6MPa (6 bar) Minimum recommended supply pressure 0.08MPa (0.8 bar) Maximum supply pressure to PRV 1.6MPa (16.0 bar) Temperature/Pressure Relief Valve 90°C/0.7MPa (7 bar)
  • Page 6: Description Of The Product

    4.2 Operation principle 4. Description of the product The product is used to heat and store hot water for use in domestic applications. 4.1 General description 4.3 Standard delivery This product is a purposed designed unvented water heater. The product has a copper inner vessel, Product which ensures an excellent standard of corrosion Fixing bracket...
  • Page 7: Before Installation

    5.3 Choice of location 5. Before installation National Wiring rules may contain restrictions concerning the installation of these products in 5.1 Installation regulations bathrooms. The product should be vertically wall mounted using the wall bracket supplied. The water WARNING connections must always be to the top of the product.
  • Page 8: Installation

    6. Installation WARNING Failure to provide adequate pressure relief 6.1 General will invalidate any guarantee and lead to a dangerous installation. After reading the previous sections in this booklet and choosing a good location for the product please Expansion can take place within the cold water install, paying attention to the following hydraulic, supply provided that both : electrical and commissioning sections.
  • Page 9: Electrical Connections

    the pressure relief device and that this pipe must be left open to the atmosphere. The pressure relief device is to be operated regularly to remove lime deposits and to verify that it is not blocked. The pipe material should be capable of conveying water/steam at 100°C.
  • Page 10: Commissioning

    Setting the “mid-range” position: 7. Commissioning Rotate the thermostat knob to the mid position. Remove the terminal cover by using a large flat bladed screwdriver to depress the three 7.1 General snap lugs located in the three top rectangular depressions. Holding the thermostat knob in After filling the installation with water in the previous position turn the terminal cover over and remove section please follow the following steps to complete...
  • Page 11: Operation

    System malfunction 8. Operation Explain how to isolate electrical and water supplies in case of a fault. Explain that qualified plumber and/or 8.1 General electrician should be contacted if there is a fault. Explain how to identify/check basic faults. WARNING Maintenance Do not block or restrict the discharge from any safety valve...
  • Page 12: Maintenance

    Earth thermostat Maintenance should be carried out by a post and thermal competent person and any replacement cut-out Thermostat parts should be authorised Heatrae Sadia securing post spare parts. Temperature / pressure Front relief valve It is recommended that maintenance is carried out annually and should include Figure 7 –...
  • Page 13: Troubleshooting

    10.1 Fault finding 10. Troubleshooting Disconnect the electrical supply before removing the terminal cover. It is recommended that any service operations on the product are carried out by a WARNING competent person. Do not tamper with any of the safety valves or controls supplied with the cylinder as this will invalidate any guarantee Symptom...
  • Page 14: Decommissioning Procedure

    Remove product ensure the correct spare part is obtained. Cap pipework Do not replace with parts not recommended by Heatrae Sadia - this will invalidate your warranty and Environmental information may render the installation dangerous. The Waste Electrical and Electronic Equipment...
  • Page 15: Accessories

    (code no. 95 970 354) is recommended. Follow the correctly. installation instructions supplied with the valve for connection to the system. 2. Any valves or controls are of Heatrae Sadia recommended type. 3. The product has not been tampered with and has been regularly maintained as detailed in these instructions.