Interfaces; Interface Configuration; Dc Power Supply - ADS-tec opc6115 User Manual

Table of Contents

Advertisement

OPC6115/6315

7 Interfaces

7.1 Interface configuration

Interface
COM1
COM2
On the left side of the case, the interfaces are arranged. All interfaces are labeled. The IEC connector or
through terminal for the power supply is located on the right side of the control system.
Note:
Under the embedded operating system Windows CE.net the communication
interfaces (COM, USB, etc.) have to be explicitly be enabled and drivers
need to be installed
Pos: 26 /Datentechnik/Schnittstellen/Spannungsversorgung/Spannungsversorgung für VMT60xx-Serie @ 2\mod_1260450284020_6.doc @ 6853 @
7.2 24V DC Power Supply
The supply voltage is provided via a lead-through terminal including a screw connection (Phoenix
Contact COMBICON MC 1,5/4-STF3.81). (The figure shows the socket inside the device).
Pin-Number
1
2
3
Technical Data of the input
•Input:
•Input current:
•current consumption:
•Max. Input current:
Note:
The power supply can be protected with a slow-blow fuse of up to 4A.
Note:
The typical power consumption of this device is indicated in the "Technical
details" chapter.
Note:
If the case is connected with earth potential at the provided PE contact (e.g. by
connecting the PE contact with the device plug), the electrical insulation is no
longer given. This also applies if the device is installed by using a metal retainer
clip.
If you want to have the device electrically insulated from the power supply,
you have to use a method of installation that ensures appropriate insulation.
© ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen
IRQ
Adress
4
3F8h
3
2F8h
Signal-Name
24V DC
PE
0V DC
Max. 130 Watt
19..30 VDC
8,5A (24 VDC)
18A
23