ELECTRICAL CONNECTIONS
3

3.5.2 Connecting the signal and field current cables, wall-mounted housing

• The outer shield of signal cable A and/or B is connected via the stranded drain wire.
• If a shielded field current cable is used, the shield must NOT
the signal converter.
• Bending radius: ≥ 50 mm / 2"
Figure 3-14: Electrical connection of the signal and field current cables, wall-mounted housing
1 Open the housing cover.
2 Pass the prepared signal cable through the cable entry and connect the corresponding strand-
ed drain wires and conductors.
3 Connect the stranded drain wire of the outer shield.
4 Pass the prepared field current cable through the cable entry and connect the corresponding
conductor.
Any shield that is present must NOT
5 Tighten the screw connections of the cable entry and close the housing cover.
INFORMATION!
Ensure that the housing gasket is properly fitted, clean and undamaged.
34
NOT
NOT be connected.
NOT
www.honeywell.com/ps
NOT be connected in the housing of
NOT
NOT
34-VF-25-53 iss.3 GLO Aug 10 US