Manufacturer Specific Parameters Of The Signal Converter For Resource Block - Honeywell TWM 9000 Supplementary Instructions Manual

Signal converter for electromagnetic flowmeters
Hide thumbs Also See for TWM 9000:
Table of Contents

Advertisement

OPERATION
4

4.4.2 Manufacturer specific parameters of the signal converter for Resource Block

Parameter
Parameter
Parameter
Parameter
Subelement
DEV_DESCRIPTION
DEV_DESCRIPTION
DEV_DESCRIPTION
DEV_DESCRIPTION
Device Description
Device Description
Device Description
Device Description
DB_DEVICE
Data Base GDC
C_NUMBER_DEVICE
C-Number Device
C_NUMBER_
PRODUCT
C-Number Production
CONVERTER_MODEL
Converter Model
LOGICAL_PLACE
Logical Place
SUPPLY_OPTION
Supply Option
DISPLAY_OPTION
Display Option
IO_SELECTION
IO1 Modules IO
IO_MODULE_A
IO2 Module Term. A
IO_MODULE_B
IO Module B
20
Access
Description and settings
R
Describes some characteristics of the device.
R
Data base version of the GDC device.
R
Current C-Number of this device.
R
C-Number of production; this number identifies the type of
electronics, can be found on the converter assembly sticker
as well.
R
The model of signal converter.
R
Setting:
Error / Standard / Extended standard / Special
R
Supply of sensor and electronics option.
Setting:
configuration error / unknown / 100...230 VAC + no option /
100...230 VAC + capacit.Elect. / 100...230 VAC + Virtual Ref /
100...230 VAC + non Ex Adapter / 12...24 VDC + no option /
12...24 VDC capacit.Elect. / 12...24 VDC + Virtual Ref /
12...24 VDC + non Ex Adapter / 24 VAC/DC + no option /
24 VAC/DC + capacit.Elect. / 24 VAC/DC + Virtual Ref /
24 VAC/DC + non Ex Adapter
R
Setting:
Configuration error or missing / Standard / Eastern Europe /
Northern Europe / Southern Europe / Far East / Japanese /
Chinese / Russian
R
Setting:
configuration error or missing / no IO selection / Basic IO / Exi
IO: CO act + PO pas / Exi IO: CO pas + PO pas /
Mod. IO: CO act, PO act/high current / Reserved /
Mod. IO: CO act, PO pas/high current /
Mod. IO: CO act, PO pas/Namur /
Mod. IO: CO pas, PO act/high current /
Mod. IO: CO pas, PO pas/high current /
Mod. IO: CO pas, PO pas/Namur / PROFIBUS PA /
Foundation Fieldbus / PROFIBUS DP / RS485 Modbus /
RS485 Modbus with active termination /
CAN Bus BATCHCONTROL /
CAN Bus BATCHCONTROL + outputs /
R
Setting:
configuration error or missing / without carrier /
Exi OPt.: CO act +PO/CI pas / Exi OPt.: CO pas + PO/CI pas /
Exi OPt.2: Currin act + PO/CI pas /
Exi OPt.2: Currin pas + PO/CI pas / Exi OPt.3: 2xCurrin act /
Incl. carrier, without IO module / Current Out act /
Current Out pas / Pulse Out act/high current /
Pulse Out pas/high current / Pulse Out pas/Namur /
Control In act/high current / Control In pas/high current /
Control In act/Namur / Tidalflux / Temperature Input /
Current Input act / Current Input pas
No module possible.
www.honeywellprocess.com
TWM 9000
Initial Value
-
Current data base
version
Current C-Number
Device
Current C-Number
Production
TWM9000
Standard
Current Supply
Option
as ordered
Foundation
Fieldbus
as ordered
-
34-VF-25-37 iss.2 GLO Jan 18 US