Omron G9SP Series Manual page 15

Safety controller
Hide thumbs Also See for G9SP Series:
Table of Contents

Advertisement

Communications cable
The suited cable is different according to the combination of component. Please
produce the cable of the following connecting wires when connecting with a
Mitsubishi Electric Standard PLC Q series (QJ71C24N-R2).
G9SP-series
RS-232C Serial Communications
Board
Connector
Signal
FG
SD
D-Sub
RD
male
RS
9-pin
CS
5V
DR
ER
SG
Sample Ladder Programming for Mitsubishi Electric PLC Q series
This section provides an example of programming to monitor Safety Input terminal
data of a G9SP-series Controller from a Mitsubishi Electric Standard PLC Q
series.
RS-232C Serial Communications Sequence
The G9SP-series Controller returns a response to the command sent from the
Standard PLC.
Receive
after 300 ms
Receive End
Receive
after 300 ms
Receive End
2 - 2
Pin No.
1
2
3
4
5
6
7
8
9
Standard PLC
Initialization
Send processing
Sent command
processing
Reception response
Receive processing
Send processing
Sent command
processing
Reception response
Receive processing
Send processing
RS-232C Serial Communications
Mitsubishi Electric Q series
serial communication module
Pin No.
Signal
Connector
1
CD
2
RD
D-Sub
3
SD
male
4
ER
9-pin
5
SG
6
DR
7
RS
8
CS
9
RI
G9SP-series Controller
Send/receive processing
Send/receive processing
2