Failsafe Alarm Relay Specifications; Copper Ethernet Port Specifications; Fiber Optic Ethernet Port Specifications - Siemens RUGGEDCOM i803 Installation Manual

Hide thumbs Also See for RUGGEDCOM i803:
Table of Contents

Advertisement

Chapter 4
Technical Specifications
Section 4.3

Failsafe Alarm Relay Specifications

NOTE
The following specifications are for Class-2 circuits only.
Maximum Switching Voltage
30 VDC
125 VDC
125 VAC
220 VDC
250 VAC
Section 4.4

Copper Ethernet Port Specifications

The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM i803.
Speed
10/100Base-TX
b
Auto-Negotiating
c
Shielded or unshielded.
d
Auto-crossover and auto-polarity.
e
Typical distance. Dependent on the number of connectors and splices.
f
RMS 1 minute.
Section 4.5

Fiber Optic Ethernet Port Specifications

The following details the specifications for fiber Ethernet ports that can be ordered with the RUGGEDCOM i803.
NOTE
• All optical power numbers are listed as dBm averages. To convert from average to peak add 3 dBm.
To convert from peak to average, subtract 3 dBm.
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens sales associate when determining maximum segment
distances.
18
Rated Switching Current
2 A, 60 W
0.24 A, 30 W
0.5 A, 62.5 W
0.24 A, 60 W
0.25 A, 62.5 W
b
Connector
Duplex
RJ45
FDX/HDX
Wiring
c
Cable Type
d
Standard
TIA/EIA
> Category 5
T568A/B
RUGGEDCOM i803
Installation Guide
Isolation
1500 V
for 1 minute
rms
Maximum
Isolation
e
Distance
100 m (328 ft)
1.5 kV
Failsafe Alarm Relay Specifications