Siemens RUGGEDCOM i803 Installation Manual
Siemens RUGGEDCOM i803 Installation Manual

Siemens RUGGEDCOM i803 Installation Manual

Hide thumbs Also See for RUGGEDCOM i803:

Advertisement

Quick Links

RUGGEDCOM i803
Installation Guide
07/2017
RC1005-EN-05
Preface
Introduction
Installing the Device
Communication Ports
Technical Specifications
Dimension Drawings
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM i803

  • Page 1 Preface Introduction Installing the Device RUGGEDCOM i803 Communication Ports Technical Specifications Dimension Drawings Installation Guide Certification 07/2017 RC1005-EN-05...
  • Page 2: Security Information

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3 RUGGEDCOM i803 Installation Guide Contacting Siemens Address Telephone E-mail Siemens Canada Ltd Toll-free: 1 888 264 0006 ruggedcom.info.i-ia@siemens.com Industry Sector Tel: +1 905 856 5288 300 Applewood Crescent Fax: +1 905 856 1995 Concord, Ontario www.siemens.com/ruggedcom Canada, L4K 5C7...
  • Page 4 RUGGEDCOM i803 Installation Guide...
  • Page 5: Table Of Contents

    RUGGEDCOM i803   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................vii Related Documents ..........................viii Accessing Documentation ........................viii Training ............................viii Customer Support ..........................viii Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................1 1.2    Description ........................... 2 Chapter 2 Installing the Device ..................
  • Page 6   RUGGEDCOM i803 Table of Contents Installation Guide Chapter 5 Dimension Drawings ..................Chapter 6 Certification ....................6.1    Approvals ........................... 23 6.1.1    CSA ..........................23 6.1.2  ATEX/IEC Ex ........................24 6.1.3  European Union (EU) ....................... 24 6.1.4    FCC ..........................25 6.1.5  FDA/CDRH ........................
  • Page 7: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM i803 (i-Series) product line. It describes the major features, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 8: Related Documents

    Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: • Access Siemens' extensive library of support documentation, including FAQs and manuals • Submit SRs or check on the status of an existing SR •...
  • Page 9: Introduction

    Gigabit Ethernet. With up to nine Ethernet ports, the RUGGEDCOM i803 is the perfect choice for a wide variety of demanding industrial environments such as those found in process control applications (oil and gas, petro-chemical, metals and mining, wind farms).
  • Page 10: Description

    • CSA/UL 60950 safety approved to 85 °C (185 °F) Section 1.2 Description The RUGGEDCOM i803 features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. Figure 1: RUGGEDCOM i803 1. Failsafe Alarm Relay    2. Power Supply Terminal Block    3. Chassis Ground Terminal    4. POWER LEDs    5. ALARM LED    6. Port Status LED   ...
  • Page 11 Illuminates when an alarm condition exists. Communication Ports Receive and transmit data, as well as provide access to the RUGGEDCOM ROS Web interface. For more information about the various ports available for the RUGGEDCOM i803, refer to Chapter 3, Communication Ports.
  • Page 12 Chapter 1 RUGGEDCOM i803 Introduction Installation Guide Description...
  • Page 13: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 14: General Procedure

    Section 2.3 Mounting the Device The RUGGEDCOM i803 can be equipped with a DIN rail bracket pre-installed on the back of the chassis. The bracket allows the device to be slid onto a standard 35 mm (1.4 in) DIN rail. To mount the device to a DIN rail, do the following: Align the slot in the bracket with the DIN rail.
  • Page 15: Connecting The Failsafe Alarm Relay (If Equipped)

    Control of the failsafe relay output is configurable through RUGGEDCOM ROS. One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the RUGGEDCOM ROS User Guide for the RUGGEDCOM i803. The following shows the proper relay connections.
  • Page 16: Connecting Power

    Section 2.5 Connecting Power The RUGGEDCOM i803 supports a single low DC power supply with reverse polarity and dual independent inputs. This allows for two redundant DC power sources with the same nominal voltage to be connected. To connect power to the device, do the following: IMPORTANT! •...
  • Page 17 RUGGEDCOM i803 Chapter 2 Installation Guide Installing the Device Figure 4: Terminal Block Wiring – Single DC Power Supply Input 1. Positive Terminal    2. Negative Terminal    3. GND Terminal    4. Chassis Ground Terminal Connect the negative wire from the power source to the negative terminal (P1- or P2-) on the terminal block.
  • Page 18: Connecting To The Device

    Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM ROS console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS User Guide for the RUGGEDCOM i803. RS232 Console Port Connect a PC or terminal directly to the RS232 console port to access the boot-time control and RUGGEDCOM ROS interfaces.
  • Page 19: Configuring The Device

    RUGGEDCOM ROS User Guide associated with the installed software release. Section 2.8 Inserting/Removing the MicroSD/MicroSDHC Card The RUGGEDCOM i803 accepts a microSD/microSDHC card to support the following features: • Configuration update and backup • Redundant firmware image • Greatly expanded logging capability •...
  • Page 20 Chapter 2 RUGGEDCOM i803 Installing the Device Installation Guide Figure 7: Inserting/Removing a MicroSD/MicroSDHC Card 1. Retention Screw    2. Access Plate    3. MicroSD/MicroSDHC Card Without touching the contacts on the card, insert or remove the microSD/microSDHC card. Install the access plate and finger-tighten the retention screw.
  • Page 21: Communication Ports

    Communication Ports Communication Ports The RUGGEDCOM i803 can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through RUGGEDCOM ROS. For more information on how to access the factory data file, refer to the RUGGEDCOM ROS User Guide for the RUGGEDCOM i803.
  • Page 22: Copper Ethernet Ports

    Section 3.1 Copper Ethernet Ports The RUGGEDCOM i803 supports several 10/100Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with RJ45 male connectors. The RJ45 receptacles are directly connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables.
  • Page 23 RUGGEDCOM i803 Chapter 3 Installation Guide Communication Ports Figure 10: LC Port 1. Tx Connector    2. Rx Connector For specifications on the available fiber optic Ethernet ports, refer to Section 4.5, “Fiber Optic Ethernet Port Specifications”. Fiber Optic Ethernet Ports...
  • Page 24 Chapter 3 RUGGEDCOM i803 Communication Ports Installation Guide Fiber Optic Ethernet Ports...
  • Page 25: Technical Specifications

    RUGGEDCOM i803 Chapter 4 Installation Guide Technical Specifications Technical Specifications This section provides important technical specifications related to the device and available modules. CONTENTS • Section 4.1, “Power Supply Specifications” • Section 4.2, “Environmental Specifications” • Section 4.3, “Failsafe Alarm Relay Specifications” •...
  • Page 26: Failsafe Alarm Relay Specifications

    220 VDC 0.24 A, 60 W 250 VAC 0.25 A, 62.5 W Section 4.4 Copper Ethernet Port Specifications The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM i803. Wiring Maximum Speed Connector Duplex Cable Type...
  • Page 27: Mechanical Specifications

    RUGGEDCOM i803 Chapter 4 Installation Guide Technical Specifications Fixed Fast Ethernet Transceivers Tx λ Power Connector Cable Tx min. Tx max. Rx Sensitivity Rx Saturation Distance Mode (typ.) Budget Type Type (μm) (dBm) (dBm) (dBm) (dBm) (typ.) (km) (nm) (dB)
  • Page 28 Chapter 4 RUGGEDCOM i803 Technical Specifications Installation Guide Mechanical Specifications...
  • Page 29: Dimension Drawings

    RUGGEDCOM i803 Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 11.7 77.5 95.3 99.5 56.5 Figure 11: Overall Dimensions...
  • Page 30 Chapter 5 RUGGEDCOM i803 Dimension Drawings Installation Guide...
  • Page 31: Certification

    RUGGEDCOM i803 Chapter 6 Installation Guide Certification Certification The RUGGEDCOM i803 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. CONTENTS • Section 6.1, “Approvals” • Section 6.2, “EMC and Environmental Type Tests”...
  • Page 32: Atex/Iec Ex

    • EEx nC IIC T4 • Ex II 3 G • 12-24 VDC, 2A, Class III Section 6.1.3 European Union (EU) This device is declared by Siemens Canada Ltd to comply with essential requirements and other relevant provisions of the following EU directives: ATEX/IEC Ex...
  • Page 33: Fcc

    • Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health Section 6.1.6 ISED This device is declared by Siemens Canada Ltd to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard:...
  • Page 34: Acma

    Section 6.1.8 RoHS This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: • China RoHS 2...
  • Page 35: Other Approvals

    • IEC 61000-6-2 Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments Section 6.2 EMC and Environmental Type Tests The RUGGEDCOM i803 has passed the following EMC and environmental tests. IEC 61850-3 Type Tests Test Description Test Levels...
  • Page 36: Environmental Type Tests

    Chapter 6 RUGGEDCOM i803 Certification Installation Guide IEEE 1613 EMC Immunity Type Tests Description Test Levels Enclosure Contact ± 8 kV Enclosure Air ± 8 kV Radiated RFI Enclosure ports 35 V/m Fast Transient Signal ports ± 4 kV @ 5 kHz DC Power ports ±...

Table of Contents