Overheating

There are several possible responses if the system overheats.

Overheat Temperature Setting

Some backplanes allow the overheat temperature to be set at 45, 50, or 55 by
changing a jumper setting. For more information, consult the backplane user manual
at www.supermicro.com. (Click Support, then the Manuals link.)

Responses

If the server overheats:
1. Use the LEDs to determine the nature of the overheating condition.
2. Confirm that the chassis covers are installed properly.
3. Check the routing of the cables and make sure all fans are present and operating
normally.
4. Verify that the heatsinks are installed properly.
3-4

Drive Carrier LEDs

The chassis includes externally accessible SAS/SATA drives. Each drive carrier
displays two status LEDs on the front of the carrier.
Activity LED
Status LED
LED Color
Blinking Pattern
Blue
Solid On
Blue
Blinking
Red
Solid On
Red
Blinking at 1 Hz
Red
Blinking with two
blinks and one stop
at 1 Hz
Red
On for five
seconds, then off
Red
Blinking at 4 Hz
Behavior for Device
SAS drive installed
I/O activity
Failure of drive with RSTe
support
Rebuild drive with RSTe support
Hot spare for drive with RSTe
support
Power on for drive with RSTe
support
Identify drive with RSTe support