4.2

LED indications

Figure 4.1 shows out view of the LED cover.
Table 4.3 shows LED indications.
Name
POW
Slow Blinking The module detected an error.
STS
WDE
ERR
TX1
RX1
TSK
IER
TX2
RX2
OP1 to 6
*1: Regarding details, refer to 4.2.1 "STS LED"
*2: When the power activation, STS LED turns on or fast blinking. If I/O assignment on CPU is done
correctly, STS LED's fast blinking changes to lighting after reset process. If I/O assignment on CPU is
not done, STS LED keeps fast blinking.
POW
TX1
TX2
OP3
ETHERNET
Figure 4.1
Table 4.3
Indication
ON
The module is in Normal operation mode.
Blinking
The module is in Utility mode.
OFF
No Power is applied.
ON
The module is OK.
Fast Blinking The module is in resetting process.
OFF
No Power is applied.
ON
The module detected Watchdog timer error.
OFF
The system software is running properly.
ON
The module detected communication error.
OFF
The module does not detect communication error.
ON
The module is sending data in Ethernet port.
OFF
The module is not sending data in Ethernet port.
ON
The module is receiving data in Ethernet port.
OFF
The module is not receiving data in Ethernet port.
ON
At least one of task code port is opened. (TCP/IP only)
OFF
None of task code port is opened.
ON
The module detected parameter error.
OFF
The module does not detect parameter error.
OFF
Unused.
OFF
Unused.
ON
ASR port No.1 to 6 is opened.
OFF
ASR port No.1 to 6 is closed.
STS
WDE
ERR
RX1
TSK
IER
RX2
OP1
OP2
OP4
OP5
OP6
EH-ETH2
Out view of the LED cover
LED indications
Description
(*1)
(*2)
4-3
Chapter.4 System equipment