Hitachi EH-150 Applications Manual page 172

Ethernet module 2 eh-eth2
Hide thumbs Also See for EH-150:
Table of Contents

Advertisement

Task
Subcommand
code
H23
Write to HI-LADDER
area
Write to parameter
area (B)
Undefined
None
H26
Memory assignment
Undefined
None
H27
End of parameter
change
H28
Change set value of
timer counter
Response task code
Code
H02
Not-executable
H03
Normal execution
Abnormal task code
Not-executable
H04 to
Abnormal task code
HFF
Abnormal task code
H00
Normal execution
(Fixed)
Abnormal task code
Not-executable
H01 to
Abnormal task code
HFF
Abnormal task code
Normal execution
Not-executable
H02
Normal execution
(Fixed)
Abnormal task code
Not-executable
Appendix B Task Codes Specifications
Return code
Code
H03
ROM memory
Occupancy code
mismatch
Not occupied
CPU is running
H00
H01
Abnormal address
Abnormal number of
steps/words
Memory over
H03
Occupancy code
mismatch
Not occupied
CPU is running
H01
Undefined
subcommand
H01
Abnormal number of
steps/words
H00
H01
Memory size over
H03
Occupancy code
mismatch
Not occupied
CPU is running
H01
Undefined
subcommand
H01
Abnormal number of
steps/words
H00
H03
Occupancy code
mismatch
Not occupied
CPU is running
H00
H01
Undefined
subcommand
Abnormal address
Abnormal number of
steps/words
Abnormal I/O code
Abnormal I/O number
H03
Inconsistent parameter
Occupancy code
mismatch
Not occupied
B-47
Error cause
Code
H01
Program memory is ROM
H03
Local station is READ-occupying CPU
H07
Local station is not occupying CPU
H0B
CPU is running and "modify during
RUN" mode is not set
H04
Transfer address is outside the designated
range of parameter area (B)
H05
Number of transfer steps are outside the
designated range
H09
"Address + number of steps" exceeds the
parameter area
H03
Local station is READ-occupying CPU
H07
Local station is not occupying CPU
H0B
CPU is running and "modify during
RUN" mode is not set
H02
Undefined subcommand is set.
H05
Only the task code is input.
H0A
Memory assignment total has exceeded
the physical memory capacity.
H03
READ-occupied by local station.
H07
Local station is not occupying CPU.
H0B
CPU is running and "modify during
RUN" mode is not set.
H02
Undefined subcommand is set.
H05
Task code input-parameter length is too
short.
H03
READ-occupying by local station.
H07
Local station is not occupying CPU.
H0B
CPU is running and "modify during
RUN" mode is not set.
H02
Subcommand is other than 02H.
Modification code is 08H or above.
H04
Address is abnormal.
H05
Task code input-parameter length is too
short.
H06
I/O code is abnormal.
Time base is H04 or above.
H07
I/O number is abnormal.
Timer counter number is 512 or above.
The 1st set value of watchdog (constant)
is greater than or equal to the 2nd set
value (constant).
0.01 second, 0.1 second or 1.0 second
was set as the time base when timer
counter number was 256 or above.
0.01 second was set as the time base
when timer counter number was 64 or
above.
H02
The timer of the timer-counter number is
used by HI-FLOW.
H03
READ-occupying by local station
H07
Not occupied by local station.