Hitachi EH-150 Series PLC Engineering Manualline

Hitachi EH-150 Series PLC Engineering Manualline

Eh-150 series plc

Advertisement

CPU Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Memory Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Base Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Power Supply Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Digital Input Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Transistor Output Modules, sink type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Transistor Output Modules, source type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Digital Output Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Analog Input Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Analog Output Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Counter Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Positioning Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Fieldbus Master Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Fieldbus Slave Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
For further information, please contact us directly.
Hitachi Europe GmbH
Arnold Rupperath
Am Seestern 18
D-40547 Düsseldorf
Phone: +49-211-5283-663
Fax: +49-211-5283-649
email: arnold.rupperath@hitachi-eu.com
Web: www.hitachi-ds.com
Hitachi Europe GmbH

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi EH-150 Series PLC

  • Page 1: Table Of Contents

    EH-150 Series PLC Engineering Guideline CPU Modules ...........2 Memory Boards .
  • Page 2: Eh-150 Series Plc

    Engineering Guideline EH-150 Series PLC CPU Modules CPU Modules Name EH-150 Type I EH-150 Type II EH-150 Type III EH-150 Type IV Model Type EH-CPU104 EH-CPU208 EH-CPU308 EH-CPU316 EH-CPU448 Number of I/O 64 points I/O modules 512 points 1024 points maximum...
  • Page 3: Digital Input Modules

    Engineering Guideline EH-150 Series PLC Digital Input Modules Item EH-XD8 EH-XD16 EH-XD32 EH-XD64 EH-XA16 EH-XAH16 Input specification DC-input AC-input I/O assignment Input voltage 24V DC 100 to 120V AC 200 to 240V AC Allowable input voltage range 19.2 to 30V DC 20.4 to 28.8V DC...
  • Page 4: Transistor Output Modules, Source Type

    Engineering Guideline EH-150 Series PLC Transistor Output Modules, Source Type Item EH-YTP8 EH-YTP16 EH-YTP16S EH-YTP32 EH-YTP64 Output specification Transistor output (source type) I/O assignment Rated load voltage 12/24V DC (+10%, -15%) Minimum switching current Leak current 0.1mA Output 0.3A 0.3A 0.8A...
  • Page 5: Analog Input Modules

    Engineering Guideline EH-150 Series PLC Analog Input Modules Item EH-AX44 EH-AX8V/H EH-PT4 Input current range 4 to 20mA Input voltage range 0 to 10V 0 to 10V (V) / -10 to 10V (H) Temperature-sensing element PT100 / PT1000 I/O assignment...
  • Page 6: Counter Modules

    Engineering Guideline EH-150 Series PLC Counter Modules Item EH-CU EH-CUE Counter pulse frequency Max. 100kHz Counter range 32bit (0 to 4,294,967,295) Number of channels 2 channels 1 channel Counter system 2 phase pulse count, 1 phase pulse count Input Counter pulse width More than 4µs...
  • Page 7: Fieldbus Master Modules

    Link area setting allways at WL1200 always at WL1200 EDS-file, File name:Eh_rmd_1_1.eds. This file can either be downloaded from File for configuration the web (www.hitachi-ds.com) or received by contacting Hitachi Europe Profibus configurator software, DeviceNet configurator RSNetworx and Configurator software Order-Number: PBDP-M-CONF...
  • Page 8: Fieldbus Slave Modules

    Engineering Guideline EH-150 Series PLC Fieldbus Slave Modules Item EH-IOCP EH-IOCD Fieldbus system Profibus-DP DeviceNet Profibus-DP slave module for use with DeviceNet slave module for use with General Type standard I/O modules of EH-150 series standard I/O modules of EH-150 series Function Max.
  • Page 9: Accessories

    9-pole Sub-D serial interface of a PC (lenght 2m). Communication cable between the serial communication ports of the CPU's EH-HEH30 to an HMI of Hitachi's EH-HMI series (lenght 3m). Ready-to-use connecting cable for the 32- and 64-point I/O modules with EH-32XY04 dedicated plug on one end, open on the other end (lenght 4m).

Table of Contents