Connecting a Fiber-Optic Cable to the Access Point

Open the electrical joint compound (supplied), and apply a liberal amount over the metal surface where
Step 3
the ground strap screw holes are located (see
Step 4
Connect the grounding lug to the access point grounding screw holes (see
two Phillips head screws (M4 x10 mm) with lock washers. Tighten the grounding screw to
22 to 24 in. lbs (2.49 to 2.71 Nm).
If necessary, strip the other end of the ground wire, and connect it to a reliable earth ground such as a
Step 5
grounding rod (see
(see
Connecting a Fiber-Optic Cable to the Access Point
The fiber-optic kit (GLC-FE-100BX-URGD=) enables the access point to support fiber-optic network
connections. The kit contains these parts:
Class 1 laser product. Statement 1008
Warning
You need a customer supplied outdoor-rated fiber-optic cable with an LC connector. The cable diameter
Note
must be 0.20 to 0.35 in. (0.52 to 0.89 cm) in diameter.
To connect a fiber-optic cable to the access point, follow these steps:
Step 1
Ensure that all power sources have been disconnected from the access point.
Warning
This unit might have more than one power supply connection. All connections must be removed to
de-energize the unit. Statement 1028
Note
Cisco Aironet 1520 Series Outdoor Mesh Access Point Mounting Instructions
40
Figure
2), an appropriate grounding point on a metal streetlight pole that is grounded
Figure
31), or a grounded cable on a cable strand.
100BASE-BX10-U rugged SFP module
Single strand fiber bidirectional optical transceiver
1.3/1.5 micro-meter wavelength division multiplexing (WDM) function
125-Mb/s data rates
Single mode LC receptacle
Eight screws
Two small take-up reels
Two large take-up reels
One liquid tight adapter—accepts a cable diameter of 0.20 to 0.35 in. (0.51 to 0.89 cm)
If your access point contains a backup battery pack, you must depress the reset button for
10 seconds or more (see the
Figure
14).
"Disabling Backup Battery Power" section on page
Figure
14) using the supplied
39).