Cisco Aironet 1520 Series Mounting Instructions page 42

Outdoor mesh access point
Hide thumbs Also See for Aironet 1520 Series:
Table of Contents

Advertisement

Connecting a Fiber-Optic Cable to the Access Point
Loosen the round end of the liquid tight connector by turning counterclockwise, but do not remove (see
Step 7
Figure
Figure 27
1
Thread end
Step 8
Carefully screw the threaded end of the adapter into the access point and hand-tighten.
Step 9
Use an adjustable wrench, the 22 mm socket, or the Sealcon S-2200-WR wrench to tighten the threaded
end of the adapter to 6 to 7 ft lbs ( 8.1 to 9.5 Nm).
Step 10
Carefully remove approximately 1 to 2 ft (30.5 cm) of the external jacket from the fiber-optic cable,
exposing the inner strand.
Carefully insert the fiber-optic LC cable connector into the rounded end of the liquid tight adapter (see
Step 11
Figure
Wrap excess fiber-optic cable around the take-up reels in a figure 8 pattern.
Step 12
Insert the fiber-optic LC cable connector into the SFP module.
Step 13
Step 14
Use an adjustable or open-end wrench to tighten the round end of the adapter to 2.7 to 3.2 ft lbs
(3.66 to 4.34 Nm).
Close the hinged cover (see the
Step 15
Cisco Aironet 1520 Series Outdoor Mesh Access Point Mounting Instructions
42
27).
Liquid -Tight Adapter
27), and push through the adapter.
"Closing the Access Point Hinged Cover" section on page
2
Round end
37).
78-18269-04