Connecting A Fiber-Optic Cable To The Ap (Air-Sfp-Kit1=) - Cisco Catalyst 9124AX Series Hardware Installation Manual

Outdoor access point
Hide thumbs Also See for Catalyst 9124AX Series:
Table of Contents

Advertisement

Installation Overview
Step 4
Loosen and remove the cable sealing nut of the cable gland by turning it counterclockwise.
Note
Caution
Step 5
Insert the Ethernet cable's unterminated end through the sealing nut end of the cable gland.
Pass the Ethernet cable through the appropriate size cable seal and pull several inches of cable through the
adapted components.
Note
Step 6
Install the CAT 6/6A RJ-45 connector on the Ethernet cable's unterminated end using your Ethernet cable
installation tool.
Follow the common CAT6/6A Ethernet connector installation procedures. Fold and crimp the connector metal
strain lug end over the outer cable jacket, foil and ground wire if equipped.
Note
Step 7
Carefully connect the RJ45 cable connector to the PoE port on the AP.
Step 8
Slide the cable gland with the rubber seal towards the AP over the RJ45 connector.
Screw the threaded screw nut of the body into the AP, and hand-tighten it.
Step 9
Slide the cable seal into the Clamp Ring fluted end, be sure it is fully seated.
Install the Seal nut on to the Clamp Ring and hand tighten enough to compress seal onto the cable jacket.
Step 10
Use an adjustable wrench or a 28–mm wrench to tighten the body's threaded end into the enclosure.
Tighten to 15 lbf-in (17 kgf-cm) of torque.
Step 11
Use an adjustable wrench and tighten the thread-lock seal nut to 15 lbf-in (17 kgf-cm) of torque.
Step 12
Route your Ethernet cable and cut off any excess cable.
Step 13
Install an RJ45 connector on the unterminated cable end and insert it into the power injector.
Note
Step 14
Turn on the power to the power injector.

Connecting a Fiber-optic Cable to the AP (AIR-SFP-KIT1=)

The optional Cisco accessory fiber-optic kit enables the AP to support fiber-optic network connections.
You can connect the fiber-optic networking cable to the SFP port. The small form-factor pluggable (SFP)
transceiver module connects the cable to the SFP port.
Verify that the cable gland has a rubber seal and ensure that it is not damaged.
If the cable gland and rubber gasket is not installed correctly, it causes the cable grip to leak.
Install the proper cable seal that fits the OD of the Ethernet cable used.
• Position and insert load bar with notches aligned to connector as shown in the figure.
• Ensure individual conductor sequence matches opposite connection end. Typical sequence
follows the T568B pinout standard.
Ensure individual conductor sequence matches opposite connection end. Typical sequence follows
T568B pinout standard.
Cisco Catalyst 9124AX Series Outdoor Access Point Hardware Installation Guide
Connecting a Fiber-optic Cable to the AP (AIR-SFP-KIT1=)
75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C9124axiC9124axdC9124axeCatalyst c9124axiCatalyst c9124axdCatalyst c9124axe

Table of Contents