– Disconnect electrical connectors at Intake Manifold Tuning
(IMT) valve position sensor -G513- -1- and at high pressure
pump -2-.
– Disconnect electrical harness connectors.
1 -
Camshaft Position (CMP) sensor 2 -G163-
2 -
Camshaft adjustment valve 2 -N208-
3 -
Camshaft adjustment valve 2 (exhaust) -N319-
4 -
Camshaft Position (CMP) sensor 4 -G301-
– Remove bolts -arrows- and disconnect electrical connections
at ignition coils.
– Set electrical wiring harness aside.
Continuation for Both Sides
– Remove ignition coils using ignition coil puller -T40039- .
Installing
Installation is in reverse order of removal.