Terminal torque settings

Table 3-2 Torque settings
Terminals
Power terminals
Control terminals
Status relay terminals
Ground terminals
Small ground terminal screws
*Torque tolerance = 10 %
Table 3-3 Plug-in terminal block maximum cable sizes
Model size
Terminal block description
All
11 way control connectors
All
2 way relay connector
3.8

Routine maintenance

The drive should be installed in a cool, clean, well ventilated location.
Contact of moisture and dust with the drive should be prevented.
Regular checks of the following should be carried out to ensure drive /
installation reliability are maximized:
Environment
Ambient
Ensure the enclosure temperature remains at or below
temperature
maximum specified
Ensure the drive remains dust free – check that the
Dust
heatsink and drive fan are not gathering dust. The
lifetime of the fan is reduced in dusty environments.
Ensure the drive enclosure shows no signs of
Moisture
condensation
Enclosure
Enclosure
Ensure filters are not blocked and that air is free to flow
door filters
Electrical
Screw
Ensure all screw terminals remain tight
connections
Crimp
Ensure all crimp terminals remains tight – check for any
terminals
discoloration which could indicate overheating
Cables
Check all cables for signs of damage
20
Electrical
Getting
Basic
Running the
installation
started
parameters
Torque setting*
1.0 N m (12.1 lb in)
0.2 N m (1.7 lb in)
0.5 N m (4.5 lb in)
4 N m (35 lb in)
2 N m (17.7 lb in)
Max cable size
2
1.5 mm
(16 AWG)
2
2.5 mm
(12 AWG)