Operations

Initial Power UP
After power up, the thermostat is reset. During system reset, all LCD icons are displayed for 2 seconds and
the keys are locked. After that, all keys are unlocked and the thermostat is initialized. Then software version is
shown.The typical reset display is shown below.
The following table shows the settings of the RT310RF digital thermostat after Power on, or after TEST/PAIRING
button is pressed:
Function
Operation Mode
Room Temperature
Setpoint Temperature
°C indicator
Frost Protection indicator
Heat indicator
Low-Battery Warning indicator Off, to be renewed within 5 seconds
Output Relay
Reviewing Setpoint Temperature
Press
or
Actual room temperature
When operating in Frost protection mode, the LCD will show frost setpoint with the Frost Protection
indicator displayed.
Press Backlight or wait 2 seconds without key press to return to normal operation, room temperature will
be displayed.
10 RT310RF Installation Manual
Status after Reset
Normal mode
22.0°C, to be renewed within 5 seconds
20.0°C
On
Off
Off
Off
to review Setpoint temperature. The flame icon won't be turned on.