TROUBLESHOOTING

PROBLEM
NO DISPLAY
PROGRAM LOCKED-OUT
MAX, MIN, TOT LOCKED-OUT
INCORRECT INPUT DISPLAY VALUE
"OLOL" in DISPLAY (SIGNAL HIGH)
"ULUL" in DISPLAY (SIGNAL LOW)
JITTERY DISPLAY
MODULES or PARAMETERS NOT ACCESSIBLE
ERROR CODE (Err 1-4)
DISPLAY ZERO'S AT LEVELS BELOW 1% OF RANGE
For further assistance, contact technical support at the appropriate company numbers listed.
PARAMETER VALUE CHART
PAX MODEL NUMBER
Signal Input Parameters

DISPLAY
PARAMETER
MODEL DEPENDENT

PAXT: INPUT TYPE

PAXT: TEMPERATURE SCALE

PAXH: INPUT COUPLE

* DISPLAY RESOLUTION

DISPLAY ROUNDING INCREMENT

PAXT: DISPLAY OFFSET

FILTER SETTING
-

FILTER ENABLE BAND - PAXH

PAXT: ICE POINT SLOPE

SCALING POINTS

SCALING STYLE - NOT PAXT

* INPUT VALUE 1
 
* DISPLAY VALUE 1
 
* INPUT VALUE 2
 
* DISPLAY VALUE 2
 
* INPUT VALUE 3
 
* DISPLAY VALUE 3
 
* INPUT VALUE 4
 
* DISPLAY VALUE 4
 
* INPUT VALUE 5
 
* DISPLAY VALUE 5
 
* Decimal point location is model and programming dependent.
REMEDIES
CHECK: Power level, power connections
CHECK: Active (lock-out) user input
ENTER: Security code requested
CHECK: Module 3 programming
CHECK: Module 1 programming, Input Range Jumper position, input connections, input signal level,
PERFORM: Module 9 Calibration (If the above does not correct the problem.)
CHECK: Module 1 programming, Input Range Jumper position, input connections, input signal level
CHECK: Module 1 programming, Input Range Jumper position, input connections, input signal level
INCREASE: Module 1 filtering, rounding, input range
CHECK: Wiring is per EMC installation guidelines
CHECK: Corresponding option card installation
PRESS: Reset KEY (If cannot clear contact factory.)
PROGRAM: Module 4 as Hi-t: 0.0 LO-t: 3271.1 (to disable zero chop feature)
Programmer ________________ Date ________
________ Meter# _____________ Security Code __________
FACTORY
USER SETTING
SETTING



PAXH
 
 

  
  

  
  

  
  
  
Module 4 Display Offset is zero, press DSP for Input Display
DISPLAY
PARAMETER
* INPUT VALUE 6
 
* DISPLAY VALUE 6
 
* INPUT VALUE 7
 
* DISPLAY VALUE 7
 
* INPUT VALUE 8
 
* DISPLAY VALUE 8
 
* INPUT VALUE 9
 
* DISPLAY VALUE 9
 
* INPUT VALUE 10
 
* DISPLAY VALUE 10
 
* INPUT VALUE 11
 
* DISPLAY VALUE 11
 
* INPUT VALUE 12
 
* DISPLAY VALUE 12
 
* INPUT VALUE 13
 
* DISPLAY VALUE 13
 
* INPUT VALUE 14
 
* DISPLAY VALUE 14
 
* INPUT VALUE 15
 
* DISPLAY VALUE 15
 
* INPUT VALUE 16
 
* DISPLAY VALUE 16
 
33
FACTORY
USER SETTING
SETTING
  
  
  
  
  
  
  
  
  
  
  